2020 43rd International Conference on Telecommunications and Signal Processing (TSP) 2020
DOI: 10.1109/tsp49548.2020.9163549
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Smart-Shoe Architecture for Podiatric Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…Further increases in force result in further decreases in resistance. It can be explained by the Equations ( 1 ) and ( 2 ), where a change in orientation of conduction path results in a change of R , change in tunneling distance results in a change of R , which in turn change the junction and deformation of MWCNT change in R , which results in overall resistance decreases [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Further increases in force result in further decreases in resistance. It can be explained by the Equations ( 1 ) and ( 2 ), where a change in orientation of conduction path results in a change of R , change in tunneling distance results in a change of R , which in turn change the junction and deformation of MWCNT change in R , which results in overall resistance decreases [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
“…On the other hand, piezoresistive pressure sensors are easy to interface with peripheral circuits, less susceptible to noise and can miniaturize the sensors [ 23 ]. Earlier, commercial sensors called force-sensing resistor (FSR) were used in foot pressure measurement systems [ 24 , 25 , 26 , 27 , 28 ], which are ultra-thin, flexible, and have a low power consumption, such as FSR402, LDT0-028K. Investigations show that over time of use, they have been deformed, and their sensitivity was degraded.…”
Section: Introductionmentioning
confidence: 99%
“…where V CC is the supply voltage and V R is the 1 MΩ resistance voltage drop. The resistance voltage drops were read with the ATmega328P µC with a f s_FSR = 100 Hz sampling frequency and, after filtering with a second-order f c_FSR = 35 Hz cutoff frequency Butterworth lowpass filter for noise removal [1,26], the FSR resistance values were determined according to (1).…”
Section: Plantar Pressures Ssessmentmentioning
confidence: 99%
“…As an essential function of the human body, examination and treatment procedures of walking are directed towards the preservation and restauration of good body mechanics in posture and in movement. Indeed, good body mechanics requires adequate joint range of motion, normal flexibility, a good neuro-muscular control, and even a good proprioception, all built on a good and healthy posture [1,2].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation