1993
DOI: 10.1016/0009-8981(93)90024-x
|View full text |Cite
|
Sign up to set email alerts
|

A one-step sandwich enzyme immunoassay for human matrix metalloproteinase 2 (72-kDa gelatinase/type IV collagenase) using monoclonal antibodies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
90
0
1

Year Published

1996
1996
2010
2010

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 158 publications
(92 citation statements)
references
References 27 publications
1
90
0
1
Order By: Relevance
“…The relationship between the normal ranges of MMPs and TIMPs and age or sex has not yet been thoroughly investigated (9)(10)(11)(12). Among the MMPs and TIMPs we examined, one published study has shown that serum levels of MMP-1 and TIMP-1 were unrelated to age (19).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The relationship between the normal ranges of MMPs and TIMPs and age or sex has not yet been thoroughly investigated (9)(10)(11)(12). Among the MMPs and TIMPs we examined, one published study has shown that serum levels of MMP-1 and TIMP-1 were unrelated to age (19).…”
Section: Discussionmentioning
confidence: 99%
“…Concentrations of MMPs 1, 2, 3, and 9, and TIMPs 1 and 2 in blood and tissue samples were measured by a single-step sandwich EIA system using a solid-phase monoclonal antibody and a horseradish peroxidase-labeled monoclonal antibody as previously described (9)(10)(11)(12)(13). For MMP-9, plasma samples instead of serum samples were used for EIA (12).…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of serum MMP-2 was measured by a onestep sandwich enzyme immunoassay (EIA) system using murine monoclonal antibodies raised against the purified proMMP-2 and an oligopeptide from residue 17 to 35 of the amino terminal region on the human MMP-2 sequence, as previously described (Fujimoto et al, 1993a). The sensitivity of this EIA system was 2.4 pg per assay (0.24 ng ml-'), and linearity was obtained between 10 and 5000 pg per assay (1.0-500 ng ml-').…”
Section: Methodsmentioning
confidence: 99%
“…The maximum diameter of each bladder tumour was determined endoscopically. The clinicopathological features of the patients are shown in Table 1.The concentration of serum MMP-2 was measured by a onestep sandwich enzyme immunoassay (EIA) system using murine monoclonal antibodies raised against the purified proMMP-2 and an oligopeptide from residue 17 to 35 of the amino terminal region on the human MMP-2 sequence, as previously described (Fujimoto et al, 1993a). The sensitivity of this EIA system was 650…”
mentioning
confidence: 99%
“…The intra-and interassays CsV for measuring MMP-2 levels were 5.4% and 8.3%, respectively. 23 The intra-and interassay CsV to evaluate MMP-9 levels were 4.9% and 8.6%, respectively. 24 …”
Section: Assessmentsmentioning
confidence: 97%