2021
DOI: 10.1016/j.aca.2020.11.006
|View full text |Cite
|
Sign up to set email alerts
|

A parameter-free framework for calibration enhancement of near-infrared spectroscopy based on correlation constraint

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…Bioactivity data can be retrieved from many specialized databases, such as the DBAAPS, APD3, DRAMP, and CAMP databases. Machine learning methods can effectively associate the peptide sequences with their bioactivity values, and we have proposed many effective algorithms. However, to the best of our knowledge, few complete works integrate a large-scale screening protocol, successful screening application, chemical synthesis, and bioactivity validation of antifungal peptides.…”
mentioning
confidence: 99%
“…Bioactivity data can be retrieved from many specialized databases, such as the DBAAPS, APD3, DRAMP, and CAMP databases. Machine learning methods can effectively associate the peptide sequences with their bioactivity values, and we have proposed many effective algorithms. However, to the best of our knowledge, few complete works integrate a large-scale screening protocol, successful screening application, chemical synthesis, and bioactivity validation of antifungal peptides.…”
mentioning
confidence: 99%
“…NS-PFCE has been applied to eliminate the calibration transfer between different instruments 46 and different mesh leaf samples. 36 These results show that the algorithms based on VCPA-IRIV-PLSR and NS-PFCE are suitable for the calibration transfer of near-infrared spectra between samples that exist in different states.…”
Section: Discussionmentioning
confidence: 72%
“…Figure 6 b shows the spectra transferred by PDS and IPCA displayed different extent differences in the whole spectra range, with the largest difference in the 1400–1900 nm region. This suggests that the spectral variations brought by spectrometer differences could be systematic differences that vary from sample to sample [ 15 ]. The difference spectra also provide evidence that the IPCA may be more effective than PDS, as the difference spectra of IPCA were more stable in the whole spectral range, while the difference spectra of PDS varied along the wavelength.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, multi-level simultaneous component analysis (MSCA) [ 13 ] was developed to explore the underlying relationship of the multivariate data involving different factors [ 14 ]. The recently proposed parameter-free framework for calibration enhancement (PFCE) applies correlation constraints on the regression coefficients [ 15 ]. Alternatively, Tikhonov regularization [ 16 , 17 ] and domain-invariant partial least squares regression (di-PLS) [ 18 ] are both based on the original model coefficients.…”
Section: Introductionmentioning
confidence: 99%