2018
DOI: 10.1016/j.ijepes.2018.01.005
|View full text |Cite
|
Sign up to set email alerts
|

A passive islanding detection strategy for multi-distributed generations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
66
0
1

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 74 publications
(67 citation statements)
references
References 27 publications
0
66
0
1
Order By: Relevance
“…This method is more accurate and effective than the passive method due to relatively small NDZs, but it has slow response toward the perturbation. In addition, the power quality and system stability may degrade due to the external variable introduced in the system [59]. However, this method requires a remarkably higher cost of implementation [49].…”
Section: Active Methodsmentioning
confidence: 99%
“…This method is more accurate and effective than the passive method due to relatively small NDZs, but it has slow response toward the perturbation. In addition, the power quality and system stability may degrade due to the external variable introduced in the system [59]. However, this method requires a remarkably higher cost of implementation [49].…”
Section: Active Methodsmentioning
confidence: 99%
“…(24) where A_CMG is the number of submicrogrids managed autonomously based on PoB, n is the maximum number of submicrogrids in the whole microgrid, Yj is the total number of breaker openings detected at the PoCs, and m is the total number of PoCs in the whole microgrid. Microgrid performance ratio (MGPR) is defined as the ratio of number of submicrogrids managed autonomously to the total number of islanding events detected at the PoC.…”
Section: Probability Of Power Balance and The State Of Probability mentioning
confidence: 99%
“…The angle is negative for any transient event in the microgrid level, and thus only grid side fault was analysed. In Abd-Elkader et al 24 , islanding was performed by opening grid circuit breaker, and there has been unnecessary disconnection of load for reducing the NDZ for lower active power mismatches. For any loss of feeder within the microgrid, the DG is disconnected, and the islanding detection time is 0.28 to 0.25 second.…”
Section: Introductionmentioning
confidence: 99%
“…At first, different features are analyzed using signal processing methods and then these features applied to a deep learning-based algorithm to classified islanding and grid connected disturbances. A voltage index has been used in Reference [29] to detect the islanding condition for large power imbalances, also for small power imbalances, the line current measured to disconnect some loads, due to transfer small imbalances to large power mismatches.…”
Section: Introductionmentioning
confidence: 99%