2017
DOI: 10.1007/s10237-017-0919-1
|View full text |Cite
|
Sign up to set email alerts
|

A patient-specific aortic valve model based on moving resistive immersed implicit surfaces

Abstract: In this paper, we propose a full computational framework to simulate the hemodynamics in the aorta including the valve. Closed and open valve surfaces, as well as the lumen aorta, are reconstructed directly from medical images using new ad hoc algorithms, allowing a patient-specific simulation. The fluid dynamics problem that accounts from the movement of the valve is solved by a new 3D–0D fluid–structure interaction model in which the valve surface is implicitly represented through level set functions, yieldi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
96
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 66 publications
(96 citation statements)
references
References 64 publications
0
96
0
Order By: Relevance
“…Several models have been formulated in this respect by considering the valves as immersed surfaces in the fluid problem either in a restricted area near the valves [31][32][33][34] or in full left heart models [35]. Several models have been formulated in this respect by considering the valves as immersed surfaces in the fluid problem either in a restricted area near the valves [31][32][33][34] or in full left heart models [35].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several models have been formulated in this respect by considering the valves as immersed surfaces in the fluid problem either in a restricted area near the valves [31][32][33][34] or in full left heart models [35]. Several models have been formulated in this respect by considering the valves as immersed surfaces in the fluid problem either in a restricted area near the valves [31][32][33][34] or in full left heart models [35].…”
Section: Introductionmentioning
confidence: 99%
“…In describing the complex fluid dynamics in the LV, which includes asymmetric vortex structures allowing an efficient filling and a natural redirection towards the aorta, one of the most difficult aspects consists in accounting for the valves in a realistic and physiologically meaningful manner. Several models have been formulated in this respect by considering the valves as immersed surfaces in the fluid problem either in a restricted area near the valves [31][32][33][34] or in full left heart models [35]. In this context, our work focuses on the treatment of the valves as orifices of infinitesimal thickness located on the boundary of the LV domain, formulating a proper set of boundary conditions (BCs) for the Navier-Stokes equations that allows a simplified but realistic treatment of the mitral and aortic valves for the study of the LV fluid dynamics.…”
Section: Introductionmentioning
confidence: 99%
“…Current ways of performing personalization include estimation of fiber directions from imaging modalities such as diffusion MRI [178], as well as data assimilation of cardiac motion from imaging into electromechanics simulations through unscented Kalman filters [164,233]. Meanwhile, in the cardiac fluid dynamics community more and more advanced patient-specific valve models incorporating fluid-structure interaction are being developed [1,73,52,81,148,175,267], and may in the future be incorporated into full-heart computational models to study the joint effect of valve function and cardiac mechanics.…”
Section: Discussionmentioning
confidence: 99%
“…Computational fluid dynamics (CFD) was used to generate patient-specific aortic valve models from patient's medical images by [4] and [5]. Other studies focus [6][7][8][9][10] on investigating the stresses on the valve leaflets excluding the fluid flow behaviour in the model.…”
Section: Introductionmentioning
confidence: 99%