A pixellated γ-camera based on CdTe detectors clinical interests and performances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2002
2002
2014
2014

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 3 publications
0
11
0
Order By: Relevance
“…The lack of energy resolution is ascribed to the presence of charge sharing between pixels at such a low level of pixel pitch ͑55 m͒. A higher pitch ͑e.g., 110 m͒ would help limit this adverse effect while still preserving high intrinsic spatial resolution, 31 and indeed a CdTe detector of the Medipix2 series similar to the one tested here but with a pitch of 110 m has been realized ͑data not shown͒.…”
Section: Figmentioning
confidence: 92%
See 2 more Smart Citations
“…The lack of energy resolution is ascribed to the presence of charge sharing between pixels at such a low level of pixel pitch ͑55 m͒. A higher pitch ͑e.g., 110 m͒ would help limit this adverse effect while still preserving high intrinsic spatial resolution, 31 and indeed a CdTe detector of the Medipix2 series similar to the one tested here but with a pitch of 110 m has been realized ͑data not shown͒.…”
Section: Figmentioning
confidence: 92%
“…This detector showed 70% intrinsic detection efficiency in the photopeak at 122 keV, with an energy window of Ϯ6.5%. 30 A European consortium including CNRS ͑Strasbourg, France͒, University of Strasbourg, CLRC ͑Rutherford Appleton Laboratory, Didcot, UK͒, and the firms Eurorad ͑Strasbourg, France͒ and Siemens AG-CRD ͑Munich, Germany͒ developed a mobile gamma camera dedicated to nuclear cardiology 31 based on a 48ϫ 48 detection matrix of 2 mm thick, independent square pixel CdTe detectors with 3.07 mm pitch, assembled in 3 ϫ 3 units each of 15ϫ 15 for an active area of 15ϫ 15 cm 2 . The detector showed an energy resolution of 5% FWHM at 122 keV, a detection efficiency of 25% at 140 keV, and an estimated intrinsic spatial resolution of 3.68 mm.…”
Section: Ib Cdte Based Compact Gamma Camerasmentioning
confidence: 99%
See 1 more Smart Citation
“…14 and 18͔͒. Matrices of segmented or continuous scintillator crystals [19][20][21][22][23][24][25] or semiconductor crystals [26][27][28][29][30][31][32][33][34][35] have been used for assembling gamma-ray imaging probes; representative data are indicated in Table I.…”
Section: Introductionmentioning
confidence: 99%
“…LETI [3] is developing a camera based on discrete CdZnTe detectors of dimensions 4 mm 4 mm and 6 mm thickness. CNRS, Eurorad, and other groups are developing a camera based on CdTe discrete detectors of dimensions 2.8 mm 2.8 mm and 2 mm thick [4], [5]. Recently, phantom imaging results were reported for a camera based on 5-mm-thick CdZnTe detectors with 2.5 mm 2.5 mm pixels [6].…”
Section: Introductionmentioning