A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Abstract: A large variety of analytical methods are available to characterize particles in aerosols and suspensions. The choice of the appropriate technique depends on the properties to be determined. In many fields information about particle size and chemical composition are of great importance. While in aerosol techniques particle size distributions of gas-borne particles are determined online, their elemental composition is commonly analyzed offline after an appropriate sampling and preparation procedure. To obtain b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…Figure (b) shows a particle-size-related ICP-MS intensity covering a 100–290 nm size range, with intensity more or less constant during the total time of analysis. The contribution of Zn in the overall PSD was efficiently resolved through the established correlation between ICP-MS and SMPS shown in previous works, even though the considerable amount of particles generated from wood treatment gives rise to a different PSD plot (Figure a). As shown in Figure c, the raw signal of the ICP-MS follows the size selection applied in the SMPS.…”
Section: Resultsmentioning
confidence: 96%
See 3 more Smart Citations
“…Figure (b) shows a particle-size-related ICP-MS intensity covering a 100–290 nm size range, with intensity more or less constant during the total time of analysis. The contribution of Zn in the overall PSD was efficiently resolved through the established correlation between ICP-MS and SMPS shown in previous works, even though the considerable amount of particles generated from wood treatment gives rise to a different PSD plot (Figure a). As shown in Figure c, the raw signal of the ICP-MS follows the size selection applied in the SMPS.…”
Section: Resultsmentioning
confidence: 96%
“…The experimental setup consisted of a tubular furnace, used as a lab-scale incinerator (Heraeus, RE 1.1), connected to the SMPS-ICP-MS, together with a rotating disk diluter (RDD) equipped with a heating tube as the introduction system. A detailed description of RDD-SMPS-ICP-MS coupling strategy and instruments specifications was already presented. , …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The SMPS provides size distributions and concentrations of NPs in air with a temporal resolution of a few minutes or less. There is ongoing interest in the benefits of coupling the SMPS to ICP-MS systems for the generation of real-time elemental data so Swiss researchers provided 33 a practical guide, including video clips, to setting up such a system and its operation. Whereas radiochemical monitoring methods are slow and time consuming for the determination of radioactive 90 Sr released during nuclear power plants accidents, a ICP-MS/MS procedure for the determination of 90 Sr in airborne particles had 34 a run-time of only 10 minutes.…”
Section: Inductively Coupled Plasma Mass Spectrometrymentioning
confidence: 99%