2006
DOI: 10.1016/j.talanta.2006.02.021
|View full text |Cite
|
Sign up to set email alerts
|

A preconcentration system using polyamine Metalfix-Chelamine resin for the on-line determination of palladium(II) and platinum(IV) by inductively coupled plasma optical emission spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(15 citation statements)
references
References 41 publications
0
15
0
Order By: Relevance
“…Solid phase extraction has been demonstrated to be a highly effective preconcentration method when first applied to spectrometric determination [14,19,20]. Among the different sorbents that were tested for this enrichment stage are resins such as polyacrylacylaminothiourea [21], imidazoline [22], Metalfix-Chelamine [23,24], Amberlite XAD-16 [25], Amberlite XAD-7 [26], Dowex 1-X10 [27], Polyorgs 17 [28], HHY-10A macropore anion resin [29], activated alumina [30] and modified silica gels like silica gel functionalized with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide [31], modified silicagel SeparonTM SGX [32], silica gel modified with propylamine groups [33]. Very good sorption properties of this last resin led us to choose it for the present study.…”
mentioning
confidence: 99%
“…Solid phase extraction has been demonstrated to be a highly effective preconcentration method when first applied to spectrometric determination [14,19,20]. Among the different sorbents that were tested for this enrichment stage are resins such as polyacrylacylaminothiourea [21], imidazoline [22], Metalfix-Chelamine [23,24], Amberlite XAD-16 [25], Amberlite XAD-7 [26], Dowex 1-X10 [27], Polyorgs 17 [28], HHY-10A macropore anion resin [29], activated alumina [30] and modified silica gels like silica gel functionalized with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide [31], modified silicagel SeparonTM SGX [32], silica gel modified with propylamine groups [33]. Very good sorption properties of this last resin led us to choose it for the present study.…”
mentioning
confidence: 99%
“…3 Thus, alkali fusion provides soluble salts of most of geological materials. [23][24][25] Dry ashing followed by dissolution of the residue with acids is often used for the digestion of biological, environmental and clinical samples. [26][27][28] Acid dissolution is extensively used for the digestion of different matrices, and can be carried out in open or closed systems, such as high-pressure ashers (HPA) [29][30][31] or high-pressure vessels heated by microwaves.…”
Section: Sorbents and Preconcentration Proceduresmentioning
confidence: 99%
“…28 Examples of noble metal determination in different kinds of materials by ICP-AES after sorption preconcentration are given in Table 2 and in original papers. 24,25,28,43,67,83,89,128,129,137,138,152,153 3·3 Inductively coupled plasma mass spectrometry Inductively coupled plasma mass spectrometry (ICP-MS) is one of the most promising methods for the determination of noble metal traces due to its low detection limits, efficiency, and multielement determination, as well as its unique capability to measure element isotopic ratios. 154,155 The popularity of ICP-MS is rapidly growing thanks to the development of a market for commercial equipment and considerable price cutting.…”
Section: ·2 Inductively Coupled Plasma Atomic Emission Spectrometrymentioning
confidence: 99%
“…However, there is no role of palladium in any biological processes and all palladium compounds are known to be highly toxic and carcinogenic [1][2][3]. Due to its economical and environmental importance, there is a necessity to determine trace concentration of palladium in environmental samples by highly sensitive analytical techniques, such as flame atomic absorption spectrometry (FAAS) [4][5][6], graphite furnace atomic absorption spectrometry [7,8], highperformance liquid chromatography [9], inductively coupled plasma atomic emission spectrometry (ICP-OES) [10][11][12], and inductively coupled plasma mass spectrometry [13].…”
Section: Introductionmentioning
confidence: 99%