1979
DOI: 10.1016/0160-5402(79)90034-2
|View full text |Cite
|
Sign up to set email alerts
|

A radioimmunoassay for alpha-melanotropin in rat plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
16
0

Year Published

1980
1980
1994
1994

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(16 citation statements)
references
References 34 publications
0
16
0
Order By: Relevance
“…Cross-reaction with 1-24 corticotrophin (Synacthen; Ciba-Geigy) was 002% that of a-melanotrophin; ß-bovine-melanotrophin (Ciba-Geigy) had a similarly weak crossreaction and produced a non-parallel displacement curve. The detection limit for the combined assay and extraction procedures was from 3 to 10 pmol -melanotrophin/l for plasma samples (Wilson & Morgan, 1979a) and 0004 pmol a-melanotrophin/pituitary gland from the present pituitary assays. The coefficient of variation of the logarithm of the plasma a-melanotrophin measurements was estimated, from the observed differences between replicated plasma measurements, as 9-5% (74 degrees of freedom).…”
Section: Animalsmentioning
confidence: 99%
See 3 more Smart Citations
“…Cross-reaction with 1-24 corticotrophin (Synacthen; Ciba-Geigy) was 002% that of a-melanotrophin; ß-bovine-melanotrophin (Ciba-Geigy) had a similarly weak crossreaction and produced a non-parallel displacement curve. The detection limit for the combined assay and extraction procedures was from 3 to 10 pmol -melanotrophin/l for plasma samples (Wilson & Morgan, 1979a) and 0004 pmol a-melanotrophin/pituitary gland from the present pituitary assays. The coefficient of variation of the logarithm of the plasma a-melanotrophin measurements was estimated, from the observed differences between replicated plasma measurements, as 9-5% (74 degrees of freedom).…”
Section: Animalsmentioning
confidence: 99%
“…Plasma samples were extracted before assay by adsorption to Florisil (Sigma Chemical Co., London; Wilson & Morgan, 1979a). The recovery in the 13 assays in which the present samples were included was 56 + 5% (mean ±s.e.m.).…”
Section: Animalsmentioning
confidence: 99%
See 2 more Smart Citations
“…Extracts were applied to: (i) Sephadex G-25 SF or G-50 SF columns (10 X 1000 mm), eluted with Anolis buffer, 0.25 M ammonium bicarbonate, pH 8.2, or 0.1 M acetic acid containing 0.5% bovine serum albumin; (ii) Amberlite XAD-2 columns, precycled, washed, and eluted as described (22) (4); (ii) a specific a-MSH assay, employing antiserum Albert (final dilution, 1:16,000) and synthetic a-MSH, iodinated by the chloramine-T method (24) and purified by Quso glass absorption (24), and chromatography on Sephadex G-25 SF, having a specific activity of 450-50 Ci/,ug (1 Ci = 3.7 X 1010 becquerels). Samples were assayed in dilutions in duplicates and sample volume (150 1,u) was 10% ofincubation volume.…”
mentioning
confidence: 99%