2009
DOI: 10.1038/nprot.2009.25
|View full text |Cite
|
Sign up to set email alerts
|

A rapid HPLC-MS/MS method for the simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human blood samples

Abstract: In the past few years, high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) has matured to a true alternative to antibody-based immunoassays in routine therapeutic drug monitoring. In transplantation medicine, mass spectrometry-based assessment of immunosuppressant drug levels is considered a gold standard diagnostic procedure. We describe a fast state-of-the-art routine online solid-phase extraction (SPE) HPLC-MS/MS analysis platform that allows monitoring of cyclosporine A, tacrolimus… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
62
0
2

Year Published

2009
2009
2024
2024

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 111 publications
(65 citation statements)
references
References 32 publications
1
62
0
2
Order By: Relevance
“…23 Chromatographic separation was performed on an Agilent 1200 system composing of a quaternary pump, a degasser, an autosampler, and a column heater (Agilent Technologies Inc). The high-performance liquid chromatography column was a Zorbax XDB-C18 (2.1 × 50 mm, 5 µm) column from Agilent.…”
Section: Determination Of Tacrolimusmentioning
confidence: 99%
“…23 Chromatographic separation was performed on an Agilent 1200 system composing of a quaternary pump, a degasser, an autosampler, and a column heater (Agilent Technologies Inc). The high-performance liquid chromatography column was a Zorbax XDB-C18 (2.1 × 50 mm, 5 µm) column from Agilent.…”
Section: Determination Of Tacrolimusmentioning
confidence: 99%
“…This technique offers analytical specificity superior to that of immunoassays or conventional highperformance/pressure liquid chromatography (HPLC) for low molecular weight analytes. LC-MS/MS has superior analytical specificity and lower reagent cost, especially if one considers the ability to multiplex several different immunosuppressive drugs (8)(9)(10). LC-MS/MS is a sensitive and selective technique that could prove useful in TDM for CyA.…”
Section: Introductionmentioning
confidence: 99%
“…DOAC quantification by LC-MS/MS was facilitated by utilizing a previously established two-dimensional chromatography setup (Agilent Technologies, Waldbronn, Germany) hyphenated to an API 4000 Qtrap instrument (ABSciex, Framingham, MA, USA) operated in the electrospray ionization (ESI) mode [11]. Based on this instrumentation, a research-use-only assay was used as previously published [2].…”
Section: Lc-ms/msmentioning
confidence: 99%