2015
DOI: 10.1016/j.aca.2014.10.015
|View full text |Cite
|
Sign up to set email alerts
|

A ratiometric electrochemical biosensor for sensitive detection of Hg 2+ based on thymine–Hg 2+ –thymine structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
50
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 113 publications
(50 citation statements)
references
References 46 publications
0
50
0
Order By: Relevance
“…Ratiometric electrochemical sensing can be achieved through either tagging both termini of nucleic acid capture probes bound to electrode surfaces with redox labels that have different oxidation potentials (29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41), manipulating host-guest or metal binding interactions on electrode surfaces with electrochemically distinguishable redox probes (42)(43)(44), or the use of redox-active probes which demonstrate a unique shift in oxidation potential selectively in the presence of the analyte (45)(46). For analytes that display target catalysis as a means of amplification within diagnostic assays, we have found the latter offers a number of benefits, such as improved reaction kinetics, since probes are not surface bound, and ease of analysis, as electrodes do not require modification prior to detection (47)(48).…”
Section: Ratiometric Electrochemical Detection Of Palladiummentioning
confidence: 99%
“…Ratiometric electrochemical sensing can be achieved through either tagging both termini of nucleic acid capture probes bound to electrode surfaces with redox labels that have different oxidation potentials (29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41), manipulating host-guest or metal binding interactions on electrode surfaces with electrochemically distinguishable redox probes (42)(43)(44), or the use of redox-active probes which demonstrate a unique shift in oxidation potential selectively in the presence of the analyte (45)(46). For analytes that display target catalysis as a means of amplification within diagnostic assays, we have found the latter offers a number of benefits, such as improved reaction kinetics, since probes are not surface bound, and ease of analysis, as electrodes do not require modification prior to detection (47)(48).…”
Section: Ratiometric Electrochemical Detection Of Palladiummentioning
confidence: 99%
“…Among these sensors, the "one-step" detection strategies have attracted considerable attentions [3,4,11,[19][20][21]. They can produce the "on" or "off" switch signal through the formation of T-Hg 2+ -T base pairs.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, ratiometric assays, including ratiometric electrochemical 24 25 26 27 28 and ratiometric electrochemiluminescent 29 30 methods, have attracted growing attentions. The ratiometric electrochemiluminescent assay, based on dual-potential electrochemiluminescence (ECL) measurement, needs to create ECL report units with two emitting states that have the potential-dependent properties upon the substrate concentration, while the ratiometric electrochemical assay needs to choose two redox probes which can be electrochemically oxidized/reduced at different potentials.…”
mentioning
confidence: 99%
“…Based on the ratio between the oxidation peak current of MB ( I MB ) and that of FCA ( I FCA ), prion was detected sensitively and selectively. In comparison with other reported ratiometric electrochemical biosensors that usually needed one multi-labeled DNA strand or at least two single-labeled DNA strands 24 25 26 27 28 , we just used only one single-labeled target aptamer to construct the ratiometric electrochemical aptasensor, which can potentially lower the cost and simplify the ratiometric E-AB sensor. Moreover, this strategy could have promising application in the detection of a wide range of analytes by changing the corresponding specific aptamers.…”
mentioning
confidence: 99%