2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference (COBEP/SPEC) 2019
DOI: 10.1109/cobep/spec44138.2019.9065398
|View full text |Cite
|
Sign up to set email alerts
|

A Review of FCS-MPC in Multilevel Converters Applied to Active Power Filters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…The optimal two switch states S opt1 (k + 1) and S opt2 (k + 1) are obtained according to the optimal solution of the objective function, and the obtained two switch states are applied to Equation (11). i p (k + 1) and v(k + 1) are obtained, and Equation ( 11) is subjected to backward difference to obtain Equation (15). In Equation ( 15), the two optimal states i p 1 (k + 1) and i p 2 (k + 1) produced by single-step predictive control continue to predict the output.…”
Section: Multi-step Predictivementioning
confidence: 99%
See 1 more Smart Citation
“…The optimal two switch states S opt1 (k + 1) and S opt2 (k + 1) are obtained according to the optimal solution of the objective function, and the obtained two switch states are applied to Equation (11). i p (k + 1) and v(k + 1) are obtained, and Equation ( 11) is subjected to backward difference to obtain Equation (15). In Equation ( 15), the two optimal states i p 1 (k + 1) and i p 2 (k + 1) produced by single-step predictive control continue to predict the output.…”
Section: Multi-step Predictivementioning
confidence: 99%
“…Concerning the problems that existed in the control method of FCS-MPC, many scholars in related fields have proposed different methods [14]. Studies [15] have considered an MPC method with time-delay compensation. The reference current is predicted by Lagrange' interpolation.…”
Section: Introductionmentioning
confidence: 99%
“…Stable DC voltage is generated by the PV system and connected to the power grid through a threephase inverter. For the current inner loop, a multistep FCS-MPC algorithm is used to control the PV + APF system to realize system functions [14,19].…”
Section: Pv System Combined With Apf System (Pv + Apf)mentioning
confidence: 99%
“…Due to the irregular and rapid variation of harmonics, the prediction corresponding to the predicted reference value has a large error at the change. Previous work [19] has pointed out that FCS-MPC was applied to an APF to compensate for the harmonic current and reactive power.…”
Section: Introductionmentioning
confidence: 99%
“…Previous work [14] has pointed out that FCS-MPC was applied to APF, to control APF to compensate harmonic current and reactive power. However, the inherent shortcomings of FCS-MPC were not improved, and vector coverage of all sectors could not be achieved, which affected the control accuracy and compensation results.…”
Section: Introductionmentioning
confidence: 99%