1986
DOI: 10.1016/0010-938x(86)90033-8
|View full text |Cite
|
Sign up to set email alerts
|

A review of impedance plot methods used for corrosion performance analysis of painted metals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
238
1
4

Year Published

2000
2000
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 637 publications
(248 citation statements)
references
References 59 publications
5
238
1
4
Order By: Relevance
“…However, it is not possible to observe these two time constants for the Ti6Al4V alloy (Figure 3). This could denote a very close relaxation time (100 Hz e 10 Hz) for the two processes 35 .…”
Section: Resultsmentioning
confidence: 80%
“…However, it is not possible to observe these two time constants for the Ti6Al4V alloy (Figure 3). This could denote a very close relaxation time (100 Hz e 10 Hz) for the two processes 35 .…”
Section: Resultsmentioning
confidence: 80%
“…The equivalent circuit (EC) proposed for fitting the EIS diagram after 1, 3, and 7 days of immersion in the presence of tannin is R s (Q 1 [R 1 (Q 2 R 2 )]) where R s represents the ohmic resistance between the reference and working electrodes, R 1 and R 2 represent the resistance or charge transfer in physical meaning [27]. The Q 1 and Q 2 parameters are the impedance related to a constant phase element (CPE) and can be attributed electrode surface or adsorbed species [27]. The CPE impedance takes into account the phenomena due to the surface heterogeneities.…”
Section: Potentiodynamic Polarizationmentioning
confidence: 99%
“…The CPE impedance takes into account the phenomena due to the surface heterogeneities. The CPE impedance is given by (2) [27]:…”
Section: Potentiodynamic Polarizationmentioning
confidence: 99%
See 1 more Smart Citation
“…R oxid and C oxid are the parameters obtained by fitting the impedance results to the parameters of the second time constant of the circuit (medium frequencies in the case of all three time constants) and referring to the oxide layer properties. Finally, the parameters C dl and R p are related to the disbonding of the coating and the onset of corrosion at the interface [17][18][19][20]. When modelling the equivalent circuit with CPE, the software gives values of capacitance in sn/ X units together with a parameter known as ''n''.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%