2012
DOI: 10.1016/j.rser.2011.08.006
|View full text |Cite
|
Sign up to set email alerts
|

A review of the economical and optimum thermal insulation thickness for building applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
171
0
7

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 367 publications
(178 citation statements)
references
References 103 publications
0
171
0
7
Order By: Relevance
“…Therefore, in this research, the additional scenarios were proposed maintaining the same materials for roof and facade but looking for the preferred insulation thickness. This limitation is seen as justified as previous studies have shown that the type of insulation material does not provide essential differences in the life cycle impact and cost of a building [46,47]. For the definition of these additional scenarios roof, facade and windows were optimized separately, from both a life cycle environmental and financial perspective, i.e.…”
Section: Definition Of the Retrofitting Scenariosmentioning
confidence: 97%
“…Therefore, in this research, the additional scenarios were proposed maintaining the same materials for roof and facade but looking for the preferred insulation thickness. This limitation is seen as justified as previous studies have shown that the type of insulation material does not provide essential differences in the life cycle impact and cost of a building [46,47]. For the definition of these additional scenarios roof, facade and windows were optimized separately, from both a life cycle environmental and financial perspective, i.e.…”
Section: Definition Of the Retrofitting Scenariosmentioning
confidence: 97%
“…According to the reliability bathtub curve [24], the failure rate of the population is an approximately low constant before the end of the lifetime. Therefore an exponential decay model is adopted from [24] in equation (13). Let θ j i denote the MTBF of the facility, then k j i is obtained from the following equation:…”
Section: Model Analysismentioning
confidence: 99%
“…The coefficients of the decay models for each intervention are shown in Table 4. As mentioned in the previous section, there are non-repairable items which applies the decay model from equation (12), and repairable items which applies the decay model from equation (13). The coefficients k j i , b j i and c j i for different interventions are given respectively in the three columns.…”
Section: Case Studymentioning
confidence: 99%
See 1 more Smart Citation
“…Kaynakli [9] reviewed all available literature on determining the optimum thickness of the thermal insulation material of a residential building and its influence on energy demand. More recently, Stevanovic [10] reviewed existing studies on several passive solar design strategies in the case of residential and commercial buildings.…”
mentioning
confidence: 99%