2005
DOI: 10.1016/j.thromres.2004.07.001
|View full text |Cite
|
Sign up to set email alerts
|

A review of the effects of the oral direct thrombin inhibitor ximelagatran on coagulation assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
38
1

Year Published

2006
2006
2010
2010

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 33 publications
(40 citation statements)
references
References 55 publications
1
38
1
Order By: Relevance
“…Thus, the PT-INR is no suitable predictor of BIBT 986 BS concentrations. In contrast, the linear correlation of plasma concentration to APTT within the dose range tested differentiates BIBT 986 from pure direct thrombin inhibitors, which have curvilinear relationship in a therapeutic dose range [5,11,13,14].…”
Section: Pdmentioning
confidence: 77%
See 2 more Smart Citations
“…Thus, the PT-INR is no suitable predictor of BIBT 986 BS concentrations. In contrast, the linear correlation of plasma concentration to APTT within the dose range tested differentiates BIBT 986 from pure direct thrombin inhibitors, which have curvilinear relationship in a therapeutic dose range [5,11,13,14].…”
Section: Pdmentioning
confidence: 77%
“…In Study 1, blood samples for coagulation tests were taken at all, but the 36-h time points as already described for PK. In Study 2, they were taken at: predose ()1 h), 24, 31.98, 32.5, 33, 34, 36, 44, and 56 h after start of infusion; and Study 3 at: predose ()1 h), 2,3,4,5,6,8,12, and 24 h after start of infusion.…”
Section: Pharmacodynamic Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…PT is a measure of the activity of the vitamin K dependent factors II, VII, IX and X and also of factor V, which is not vitamin K dependent. Although its use to measure the anticoagulant effect of warfarin in patients in a concentration-dependent manner is well established, it has been reported to have low sensitivity to therapeutic plasma melagatran concentrations in patients [13]. APTT is prolonged when any of the factors VIII, IX and X in the intrinsic system are inhibited such as by DTIs and warfarin.…”
Section: Haematological Measurementsmentioning
confidence: 99%
“…APTT is prolonged when any of the factors VIII, IX and X in the intrinsic system are inhibited such as by DTIs and warfarin. ECT is prolonged when thrombin is inhibited and can provide a measure of the effect of ximelagatran [13] but not warfarin.…”
Section: Haematological Measurementsmentioning
confidence: 99%