2022
DOI: 10.11591/ijeecs.v25.i2.pp656-665
|View full text |Cite
|
Sign up to set email alerts
|

A review on power quality issues in electric vehicle interfaced distribution system and mitigation techniques

Abstract: Electric vehicles (EV) penetration in the distribution systems is evident and intended to grow day by day. Power quality issues pop up in the distribution system with an increase in EV penetration. Distribution networks need to consider the power quality issues developed due to the penetration of EVs for planning and designing the system. The power quality issues, including voltage imbalance, total harmonic distortion, distribution transformer failure, and related issues, are anticipated due to EV penetration … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 54 publications
0
10
0
Order By: Relevance
“…The scaling values for θ1=0.3, θ2=0.007, θ3=10 is predefined to set the controller. In case of overload demand on AC load bus it will impact on the AC generation power grid given in (7).…”
Section: Control Of Ilcs 31 Control Of Ilc-1 For 3-phasementioning
confidence: 99%
See 1 more Smart Citation
“…The scaling values for θ1=0.3, θ2=0.007, θ3=10 is predefined to set the controller. In case of overload demand on AC load bus it will impact on the AC generation power grid given in (7).…”
Section: Control Of Ilcs 31 Control Of Ilc-1 For 3-phasementioning
confidence: 99%
“…Electric vehicle is the present trend attracting researchers for integrating to MG, nano grid (NG) for two-way power flow through energy storage system (ESS), the power quality problems associate to grid are discussed with optimal solution by connecting filter and restorer [6]. A review paper discusses the power quality issues in bidirectional power flow in electric vehicle to grid [7]. To reduce the total harmonic distortion (THD) in a single-phase inverter a control technique confined band variable switching frequency pulse width modulation (CB-VSFPWM) is designed [8].…”
Section: Introductionmentioning
confidence: 99%
“…Ideal placement of FACTS devices in IEEE 33 and 57 bus s ystems is determined using a sophisticated GWO and DSTATCOM with BO that adjusts for DVR [55] Power quality issue mitigation Vehicle-grid (V2G) grid-vehicle (G2V) analysis of current power quality problems and possible solutions [56] Hybrid active power filter (HAPF) SRF theory P-Q theory SVPWM HAPF is designed so that the VA rating of the active filter goes down while the filtering efficiency of the passive filter goes up [57] Power quality Harmonic elimination…”
Section: Distribution Generation Unitsmentioning
confidence: 99%
“…The abundant usage of rectifiers in the third rail systems can cause severe harmonic distortion [7]- [9]. Harmonic distortions give rise to many technical issues including degradation of transformers [10], [11] and electric motors [12], low power factor, malfunction of protective relays, increase of power losses, resonance [13], [14], and interference to communication devices [15]. For example, the use of 12-pulse rectifiers in the third rail system has generated a significant amount of 11 th and 13 th order harmonics, resulting in significant harmonic pollution to the rail system [16].…”
Section: Introductionmentioning
confidence: 99%