2008
DOI: 10.1302/0301-620x.90b10.21293
|View full text |Cite
|
Sign up to set email alerts
|

A revolution in the management of fractures of the distal radius?

Abstract: The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
81
0
7

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(89 citation statements)
references
References 67 publications
1
81
0
7
Order By: Relevance
“…After the introduction of the volar plate in the early 1990s locking plates are currently gaining popularity because of their high stability and improved fixation in osteoporotic bone [12,13]. In 2008, there were already more than 30 different volar plating systems [14]. However, to date there is no level 1 evidence of improved performance and there are considerable drawbacks including the high costs [15].…”
Section: Introductionmentioning
confidence: 99%
“…After the introduction of the volar plate in the early 1990s locking plates are currently gaining popularity because of their high stability and improved fixation in osteoporotic bone [12,13]. In 2008, there were already more than 30 different volar plating systems [14]. However, to date there is no level 1 evidence of improved performance and there are considerable drawbacks including the high costs [15].…”
Section: Introductionmentioning
confidence: 99%
“…12 We have used both patient derived functional outcome measures as well as range of motions to have both objective as well as subjective assessments. Radiological parameters were also assessed at various intervals to notice the effect of various parameters on change in functional outcome.…”
mentioning
confidence: 99%
“…When the quality of the pronator quadratus muscle is good, the volar-placed plates are almost covered with the pronator quadratus, except at the distal edge of the plate (17,18). Volar scars are better tolerated and less obvious, and the blood supply to the radius is less likely to be disrupted (17).…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, fixed-angle distal radius volar locking plates are systems that are angled to fit the palmar surface anatomically and have locking screws to fit the subchondral area at a fixed angle. These features facilitate the reduction, and fixation becomes more stable (17). This is crucial for an older population that encounters such fractures due to osteoporotic bone formation (2,9).…”
Section: Introductionmentioning
confidence: 99%