A semiautomated enzymatic method for determination of nonesterified fatty acid concentration in milk and plasma

Abstract: An enzymatic assay for the determination of nonesterified fatty acid concentrations in milk and plasma is described. The procedure is semiautomated for use with a plate luminometer or plate spectrophotometer and enables routine batch processing of large numbers of small samples (< or =5 microL). Following the activation of nonesterified fatty acids (NEFA) by acylCoA synthetase, the current assay utilizes UDP-glucose pyrophosphorylase to link inorganic pyrophosphate to the production of NADH through the reactio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(23 citation statements)
references
References 27 publications
0
23
0
Order By: Relevance
“…We measured TNF‐R1 levels by ELISA (R&D Systems, Minneapolis, MN) that permits accurate assessment with little or no TNF‐β or other interleukin cross‐reactivity and a CV of <10%. We also measured NEFA levels by enzymatic acyl‐CoA synthetase—acyl‐CoA oxidase spectrophotometric methods using the Wako NEFA‐C kit (Wako Pure Chemical Industries Ltd., Osaka, Japan), which is not different from gas chromatographic results (35). Each commercial assay was calibrated with standards from the manufacturer.…”
Section: Research Methods and Proceduresmentioning
confidence: 99%
“…We measured TNF‐R1 levels by ELISA (R&D Systems, Minneapolis, MN) that permits accurate assessment with little or no TNF‐β or other interleukin cross‐reactivity and a CV of <10%. We also measured NEFA levels by enzymatic acyl‐CoA synthetase—acyl‐CoA oxidase spectrophotometric methods using the Wako NEFA‐C kit (Wako Pure Chemical Industries Ltd., Osaka, Japan), which is not different from gas chromatographic results (35). Each commercial assay was calibrated with standards from the manufacturer.…”
Section: Research Methods and Proceduresmentioning
confidence: 99%
“…Plasma FFA levels were measured using an enzymatic spectrophotometric method (Wako Chemical, Neuss, Germany), following the manufacturer's instructions [16].…”
Section: Determination Of Serum Non-esterified Fatty Acid Levelsmentioning
confidence: 99%
“…Plasma NEFA concentration was determined according to Christmass et al (1998b). The coupled luminometric assays were further modi®ed for rapid sample throughput using a Dynatech ML 2250 microtiter plate luminometer (Dynatech Laboratories, Chantilly, Va., USA) according to Thompson et al (1997).…”
Section: Plasma Metabolite Analysismentioning
confidence: 99%