A sensitive spectrophotometric method for lead determination by flow injection analysis with on-line preconcentration

Abstract: A new flow injection (FI) system for the determination of Pb(II) at trace level with a preconcentration step and spectrophotometric detection is proposed. It is based on preconcentration of lead ions on chitosan and dithizone-lead complex formation in aqueous medium (pH 9). The chemicals and FIA variables influencing the performance of the system were optimized and applied to the determination of lead in natural, well, and drinking water samples. It is a simple, highly sensitive, and low cost alternative metho… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
24
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(25 citation statements)
references
References 14 publications
1
24
0
Order By: Relevance
“…Dithizone is an old and wellknown reagent, which was widely used for heavy metal determination (Di Nezio et al 2004). The experimental procedure for the rapid colorimetric Pb determination in soil extracts is as follows: 2 ml of soil extract were placed into one of the test tubes and treated with 2 ml of concentrated ammonia solution.…”
Section: Colorimetric Determination Of Heavy Metalsmentioning
confidence: 99%
“…Dithizone is an old and wellknown reagent, which was widely used for heavy metal determination (Di Nezio et al 2004). The experimental procedure for the rapid colorimetric Pb determination in soil extracts is as follows: 2 ml of soil extract were placed into one of the test tubes and treated with 2 ml of concentrated ammonia solution.…”
Section: Colorimetric Determination Of Heavy Metalsmentioning
confidence: 99%
“…Flow injection analysis (FIA) can provide the necessary requirement of rapid, less contamination of samples, on-line elimination of interferences and possibility of using unstable reagents (1) , high precision enhancement of on-line sensitivity, micro sample analysis, Low cost, high sample throughput , excellent accuracy (2,3) , reproducible mixing for chemiluminescence. FIA also provides portable, low cost automated reactions, whilst CL provides rapid, sensitive and selective detection using simple instrumentation (4) .…”
Section: Introductionmentioning
confidence: 99%
“…In both cases, it could be either delivered to the environment by inadequate manufacturing processes or caused by accident (Naseri et al, 2008). The environmental and health problems arise fundamentally from the use of gasoline antiknock products and paint pigments (Nezio et al, 2004). As a consequence, the world health organization (WHO) has established the maximum allowable limit of 10 ng mL À1 for lead in drinking water (WHO, 1996).…”
Section: Introductionmentioning
confidence: 99%