2008
DOI: 10.1097/ftd.0b013e31815f4f7e
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Fast Method for Quantification of Ertapenem using Meropenem as Internal Standard in Human Plasma in a Clinical Setting

Abstract: A high-performance liquid chromatography method for the determination of ertapenem in human plasma using ultraviolet detection (300 nm) was developed and validated. The method involved a simple organic protein precipitation that guarantees rapid sample preparation. By using meropenem as internal standard, it also guarantees improved precision (relative standard deviation <3.70) and accuracy (deviation from true value <6.58%). The method was linear from 0.59 to 150 microg/mL and reproducible. In conclusion, thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…Several papers have described therapeutic drugmonitoring assays for ertapenem [25][26][27][28] and a similar approach for detection of enzyme-mediated hydrolysis of b-lactam antibiotics using MALDI-TOF instruments, which are currently being used in clinical microbiology laboratories for bacterial future science group identification [18][19][20][21]. We propose that the use of LC-MS/MS described here offers multiple advantages over MALDI-TOF for the detection of carbapenemase activity.…”
Section: Discussionmentioning
confidence: 99%
“…Several papers have described therapeutic drugmonitoring assays for ertapenem [25][26][27][28] and a similar approach for detection of enzyme-mediated hydrolysis of b-lactam antibiotics using MALDI-TOF instruments, which are currently being used in clinical microbiology laboratories for bacterial future science group identification [18][19][20][21]. We propose that the use of LC-MS/MS described here offers multiple advantages over MALDI-TOF for the detection of carbapenemase activity.…”
Section: Discussionmentioning
confidence: 99%
“…To quantify ceftazidime, ciprofloxacin, flucloxacillin, linezolid, meropenem, metronidazole, piperacillin, rifampicin, and voriconazole, HPLC methods with UV detection were used. All HPLC methods have been previously described (8-10) and were in line with the Valistat 2.0 validation criteria as required by the German Society of Toxicology and Forensic Chemistry (GTFCh); linearity was proven to be within the requested concentration range across all drugs, and quality control samples at 3 different concentrations featured a relative standard deviation (RSD%) for inter- and intraday precision of <10% across all methods. An external standard method was used to quantify drug concentrations, and no protein precipitation was performed for the aqueous solutions.…”
Section: Methodsmentioning
confidence: 99%
“…Various chromatographic methods with UV detection were developed to measure total plasma concentrations of carbapemens in plasma . These assays concern mainly imipenem [5][6][7][8][9]21], meropenem [10,12,[14][15][16][17][18][19]21] and ertapenem [11,[21][22][23][24][25]. Two assays based on ultrafiltration [20] and solid phase extraction [13] were only reported for doripenem.…”
Section: Introductionmentioning
confidence: 99%