2015
DOI: 10.7454/mss.v19i2.4736
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Safe Spectrophotometric Method for Iodide Determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 7 publications
0
8
0
3
Order By: Relevance
“…The concentration of total protein was measured using the Bradford protein assay with bovine serum albumin as a standard [ 60 ]. The starch concentration was measured using the iodine starch method [ 61 ]. The measurements for both of these assays were performed spectrophotometrically at 595 nm and 615 nm, respectively, using an Infinite 200 PRO NanoQuant Microplate Reader (Tecan, Männedorf, Switzerland).…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of total protein was measured using the Bradford protein assay with bovine serum albumin as a standard [ 60 ]. The starch concentration was measured using the iodine starch method [ 61 ]. The measurements for both of these assays were performed spectrophotometrically at 595 nm and 615 nm, respectively, using an Infinite 200 PRO NanoQuant Microplate Reader (Tecan, Männedorf, Switzerland).…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of total protein was measured using the Bradford protein assay with bovine serum albumin as a standard (Bradford, 1976). The starch concentration was measured using the iodine starch method (Sulistyarti et al, 2015). The measurements for both of these assays were performed spectrophotometrically at 595 nm and 615 nm respectively, using an Infinite 200 PRO NanoQuant Microplate Reader (Tecan, Switzerland).…”
Section: Determination Of Ph Protein and Carbohydrate Concentration In Pj Mediummentioning
confidence: 99%
“…Muralidhara (1998) (Muralidhara, 1998). Sulistyarti (2015) melaporkan bahwa iodida teroksidasi oleh iodat membentuk iodium yang dengan adanya amilum membentuk larutan kompleks biru jernih yang dapat dideteksi menggunakan spektrofotometer pada λ 618 nm. Oleh karena itu, penelitian ini bertujuan untuk mengembangkan metode analisis merkuri(II) secara spektrofotometri secara tidak langsung (indirect spectrophotometry) berdasarkan pembentukan kompleks biru amilum-iodium menggunakan system pereaksi iodida-iodat.…”
Section: Pendahuluanunclassified
“…Hanya ion iodida yang tersisa akan dioksidasi oleh iodat menjadi iodium yang menghasilkan warna biru dengan absorbansi yang lebih rendah (Sulistyarti et al, 2015).…”
Section: Pendahuluanunclassified
See 1 more Smart Citation