2014
DOI: 10.5582/bst.2014.01002
|View full text |Cite
|
Sign up to set email alerts
|

A simple, rapid, economical, and practical method for the determination of efavirenz in plasma of Chinese AIDS patients by reverse phase high-performance liquid chromatography with ultraviolet detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 54 publications
0
3
0
Order By: Relevance
“…Efavirenz C 0 was determined by reverse-phase high-performance liquid chromatography with ultraviolet detection, according to our previously described method. 35 HPLC was performed using LC-20A (Shimadzu, Japan) consisting of a column compartment CTO-20A, degasser DGU-20A5, pump CBM-20A, auto-sampler SIL-20AC, and an SPD-20AV UV detector. The column was YMC-Pack ODS-A column (C18; 150 mm × 4.6 mm, 5 μm) with a pre-column (ZORBAX Eclipse Plus-C18).…”
Section: Methodsmentioning
confidence: 99%
“…Efavirenz C 0 was determined by reverse-phase high-performance liquid chromatography with ultraviolet detection, according to our previously described method. 35 HPLC was performed using LC-20A (Shimadzu, Japan) consisting of a column compartment CTO-20A, degasser DGU-20A5, pump CBM-20A, auto-sampler SIL-20AC, and an SPD-20AV UV detector. The column was YMC-Pack ODS-A column (C18; 150 mm × 4.6 mm, 5 μm) with a pre-column (ZORBAX Eclipse Plus-C18).…”
Section: Methodsmentioning
confidence: 99%
“…The HPLC (Shimadzu, Kyoto, Japan) system consists of a binary pump (LC-20AD), equipped with UV/Visible detector (SPD-A20), a Rheodyne injector port (7725i) with 20 μl loop volume and the data [19,20]. To 200 µl rabbit plasma (blank/test/CS/QC) sample transferred in an eppendorf tube (2 ml) quadruple volume (800 ml) of ACN and 20 µl WS solution of RAB (5 µg/ml) was added as extraction reagent and IS respectively, capped and vortexed on a cyclomixture for 1 min.…”
Section: Instrumentation and Chromatographic Conditionmentioning
confidence: 99%
“…During the research and development of anticancer agent GLB, the pharmacokinetic profile is needed for understanding the absorption, distribution, metabolism and excretion (ADME) of GLB in vivo 22 . The high performance liquid chromatographic - ultraviolet detector (HPLC-UV) is a conventional quantitative analysis method 23 24 25 26 . In according to the ultraviolet absorption wavelength, elution retention time and chromatographic peak area, the content of compound can be accurately measured 27 28 29 30 .…”
mentioning
confidence: 99%