2000
DOI: 10.1016/s1350-4487(99)00247-4
|View full text |Cite
|
Sign up to set email alerts
|

A simple transformation for converting CW-OSL curves to LM-OSL curves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
34
0
5

Year Published

2006
2006
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(41 citation statements)
references
References 10 publications
2
34
0
5
Order By: Relevance
“…4. The analysis of the pseudo LM-OSL curves (Bulur, 2000) confirmed the presence of a dominant fast decay and a medium decay component in aliquots of all three samples, comparable to those published previously for quartz (Durcan and Duller, 2011;Pawley et al, 2010;Singarayer et al, 2003;Jain et al, 2003). The proportion of the medium decay component varied and appeared to be relatively much weaker in aliquots of sample 316-3.…”
Section: Osl Characteristics -Small Aliquotssupporting
confidence: 87%
“…4. The analysis of the pseudo LM-OSL curves (Bulur, 2000) confirmed the presence of a dominant fast decay and a medium decay component in aliquots of all three samples, comparable to those published previously for quartz (Durcan and Duller, 2011;Pawley et al, 2010;Singarayer et al, 2003;Jain et al, 2003). The proportion of the medium decay component varied and appeared to be relatively much weaker in aliquots of sample 316-3.…”
Section: Osl Characteristics -Small Aliquotssupporting
confidence: 87%
“…Our transformation ͓Eq. ͑15͔͒ differs from Bulur's, 14 who proposed that Eq. ͑14͒ can be obtained by a conversion of the I CW signal through a transformation of the time t into u = ͱ 2tP with P͑s͒ as the stimulation period.…”
Section: Pseudo-lm-oslmentioning
confidence: 76%
“…Later on, Bulur 14 showed that this LM-OSL signal can also be obtained from the CW-OSL signal by a simple mathematical transformation. Such a signal not obtained by the modulation of the stimulation intensity but through the transformation of the CW-OSL signal is called a pseudo-OSL signal.…”
mentioning
confidence: 99%
“…where n 0 is the initial trap concentration; B is a constant describing the decay of luminescence curve and is proportional to the photoionization cross section and the intensity of light I 0 (B = I 0 ) Bulur [25]. A new independent variable, u, is described to transform the CW-OSL curve to LM-OSL.…”
Section: Linear Modulation Technique (Lm-osl)mentioning
confidence: 99%