A Six Sensor Array of Coated-Wire Electrodes for Use in a Portable Flow Injection Analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(9 citation statements)
references
References 33 publications
0
9
0
Order By: Relevance
“…Miniaturisation of sensors may reduce significantly the required sample volume [6,69,70] which may be important in the analysis of biological samples like sweat [71]. However, the most appropriate format is an integrated sensor array which may be easily combined with a microliter volume flow cell to detect various species in a small sample volume [10,55,72,73].…”
Section: Sensor Arrays In Flow-injection Analysis Systemsmentioning
confidence: 99%
See 3 more Smart Citations
“…Miniaturisation of sensors may reduce significantly the required sample volume [6,69,70] which may be important in the analysis of biological samples like sweat [71]. However, the most appropriate format is an integrated sensor array which may be easily combined with a microliter volume flow cell to detect various species in a small sample volume [10,55,72,73].…”
Section: Sensor Arrays In Flow-injection Analysis Systemsmentioning
confidence: 99%
“…Miniaturised sensors based on ISFETs, solid-contact or screen-printed electrodes may be placed in parallel or on a single substrate in a flow-through cell thus minimising the whole set-up and required sample volume. But in these cases the number of sensors normally does not exceed 6-8 [55,6]. The active site of a LAPS device where the photocurrent is generated is defined by a spot of the illuminating light.…”
Section: Applications Of Potentiometric Sensor Arraysmentioning
confidence: 99%
See 2 more Smart Citations
“…Innovations in the fabrication technology have been recently attracting attentions of the numerous researchers to ionselective electrodes (ISEs) for obtaining robust and miniaturized electrodes, and flow-through cells as detectors in ion chromatography [1][2][3][4][5] and flow injection analysis (FIA) [6][7][8][9][10][11]. Classical PVC membrane ISEs with internal filling solution have obstacles for the miniaturisation process.…”
Section: Introductionmentioning
confidence: 99%