A Smart Cell Monitoring System Based on Power Line Communication—Optimization of Instrumentation and Acquisition for Smart Battery Management

Abstract: Energy density of current generation battery packs is insufficient for next generation electric vehicles nor the electrification of the aerospace industry. Currently, approximately a third of energy density is lost due to ancillary demands (e.g., cooling and instrumentation) within a pack, relative to cell energy density. Smart cells, instrumented cells with sensors and circuitry, offer a means to monitor cell performance (e.g. temperature, voltage, current data). Uniquely here we demonstrate our 21700 cells i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 54 publications
(79 reference statements)
1
8
0
Order By: Relevance
“…Capacity measurements were taken by performing the RPT every 20 cycles, with all experiments performed within a climatic chamber (25 °C constant). This extends our previous studies [14,29], where the cells were tested for periods of <50 cycles, without capacity measurement. The sensor reliability and possible impact on the cell performance were not comprehensively assessed.…”
Section: Introductionsupporting
confidence: 82%
See 3 more Smart Citations
“…Capacity measurements were taken by performing the RPT every 20 cycles, with all experiments performed within a climatic chamber (25 °C constant). This extends our previous studies [14,29], where the cells were tested for periods of <50 cycles, without capacity measurement. The sensor reliability and possible impact on the cell performance were not comprehensively assessed.…”
Section: Introductionsupporting
confidence: 82%
“…2 (b); the cell is installed in a test rig (c), which is allows battery cycler channel cables to be connected for the ageing cycling experiments. In addition to the internal thermistor sensing, a prototype bus-bar current sensor is installed for each cell (detailed in previous works [14,29]). A concept smart cell (an intermediary design, incorporating the flexible PCB and interface PCB secured in a cap) is shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…A power line communication (PLC) system enables the power network to be additionally used as a communication channel. It therefore eliminates the need for a specific wiring harness for communication, as the existing power bus bar within the battery pack is utilised [9], [10]. Existing research on the effectiveness and limitations of in-situ PLC within a Li-ion battery pack and its dependence on SoC is limited.…”
Section: Introductionmentioning