2009
DOI: 10.1021/ef900760k
|View full text |Cite
|
Sign up to set email alerts
|

A Statistic that Identifies Errant Standard Preparation and Instrument Nonlinearity Demonstrated with Mercury Standards Prepared by Blending NIST Fossil Fuel CRMs of Similar Matrices

Abstract: Two coal certified reference materials (CRMs) for mercury content were blended, and their results checked, resulting in National Institute of Standards and Technology (NIST) traceable standards at mercury concentrations intermediate to parent certified values. How are CRM blends checked? Intervalrepeatability is a new statistic that can be employed as a quality control test to identify incorrectly prepared working standards or nonlinear instrument response over a targeted concentration interval based upon the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2010
2010
2010
2010

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…This example shows simulated data for all of the standards mixed as well as one of the unblended parent SRMs. In this example, the interval between SRM 2693 and the highest concentration blended standard falls outside the interval-repeatability limit of the method used and fails the I r QC test. This failure could be due to several causes, such as material heterogeneity, operator error, or the standard concentration being outside of the linear range of the instrument.…”
Section: Resultsmentioning
confidence: 93%
See 4 more Smart Citations
“…This example shows simulated data for all of the standards mixed as well as one of the unblended parent SRMs. In this example, the interval between SRM 2693 and the highest concentration blended standard falls outside the interval-repeatability limit of the method used and fails the I r QC test. This failure could be due to several causes, such as material heterogeneity, operator error, or the standard concentration being outside of the linear range of the instrument.…”
Section: Resultsmentioning
confidence: 93%
“…The QC test requires the user to enter the measured concentrations for each standard analyzed and the repeatability limit ( r ) of the method used. This measured concentration is compared to the concentration calculated for the blend and the interval repeatability limit of the measurement method, as described previously . At least one blended standard and one of the unblended certified parent standards must be prepared and measured for a QC test to be performed.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations