A Stimulus Artifact Removal Technique for SEMG Signal Processing During Functional Electrical Stimulation

Abstract: GA-AMF could provide technical support for improving EMG feedback control of FES rehabilitation system.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
27
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 31 publications
(28 citation statements)
references
References 27 publications
0
27
0
1
Order By: Relevance
“…EMG signals are affected by the stimulation artefacts caused by the stimulation current when NMES is used. This has been partially addressed in the literature with, for example, use of an EMG-amplifier with shut-down control [43], advanced filtering procedures [44] and optimizing the positioning of the EMG electrodes in relation to the stimulation electrodes [45]. However, these approaches do not fully eliminate the stimulation artefacts and we, therefore, were unable to use EMG as a validation of the method.…”
Section: Discussionmentioning
confidence: 99%
“…EMG signals are affected by the stimulation artefacts caused by the stimulation current when NMES is used. This has been partially addressed in the literature with, for example, use of an EMG-amplifier with shut-down control [43], advanced filtering procedures [44] and optimizing the positioning of the EMG electrodes in relation to the stimulation electrodes [45]. However, these approaches do not fully eliminate the stimulation artefacts and we, therefore, were unable to use EMG as a validation of the method.…”
Section: Discussionmentioning
confidence: 99%
“…A wavelet-based denoising method with soft threshold was utilized. The db4 wavelet was chosen as mother wavelet because its shape is similar to that of a heart sound signal, and the scale was established as 7 based on signal–noise-ratio (SNR) and normalized root mean squared error (NRMSE) [ 13 ]. The denoised heart sound was written as .…”
Section: Methodsmentioning
confidence: 99%
“…Nestes casos, diversos algoritmos de modelagem adaptativa e remoção de artefato foram propostos 1,6,7,8 , os quais utilizam um sinal de referência a fim de estimar o artefato que deve ser removido. Esse sinal de referência pode ser obtido tanto através de um segundo eletrodo quanto de um segundo estimulo feito de forma a não gerar onda M 1 .…”
Section: Introductionunclassified