A strategy for determination of systolic, mean and diastolic blood pressures from oscillometric pulse profiles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 2 publications
0
17
0
Order By: Relevance
“…As a conclusion, a measurement device with fixed ratios for determining systolic, mean and diastolic blood pressure may significantly overestimate them. [19] Moraes and Cerulli (1999 and 2000) also studied the characteristic ratios using computercontrolled linear cuff pressure deflation with 10 patients and 75 volunteers, using the auscultatory method as a reference [20,21]. A fixed percentile rule yielded a value of 56% for systolic and 76% for diastolic pressure.…”
Section: Oscillometric Methodsmentioning
confidence: 99%
“…As a conclusion, a measurement device with fixed ratios for determining systolic, mean and diastolic blood pressure may significantly overestimate them. [19] Moraes and Cerulli (1999 and 2000) also studied the characteristic ratios using computercontrolled linear cuff pressure deflation with 10 patients and 75 volunteers, using the auscultatory method as a reference [20,21]. A fixed percentile rule yielded a value of 56% for systolic and 76% for diastolic pressure.…”
Section: Oscillometric Methodsmentioning
confidence: 99%
“…The arterial volume pulse will be at maximum when the transmural pressure is zero, which occur when MAP is equal to cuff pressure [66]. MAP is not commonly estimate on clinical practice and other methods of blood pressure measurements and usually is not presented on the The oscillation or Oscillometric pulses can be extracted from cuff deflation pressure waveform and presented a signal knows as Oscillometric waveform (OMW) [57]. Filtering and deterending are used to extract OMW from cuff deflation pressure waveform [55] [58] [59].…”
Section: Oscillometric Methodsmentioning
confidence: 99%
“…The non-invasive measurements were done at the opposite arm. As noted above, precision values of SBP and DBP obtained by the oscillometric method are linked to the strategy followed by the algorithms used and their parameters (Moraes and Cerulli 2000;Ehrmann et al 2009). Two methods are commonly used: the method of maximum amplitude and the gradient.…”
Section: Resultsmentioning