2001
DOI: 10.1002/rcm.274
|View full text |Cite
|
Sign up to set email alerts
|

A strategy for quantitative bioanalysis of non‐polar neutral compounds by liquid chromatography/electrospray ionization tandem mass spectrometry: determination of TS‐962, a novel acyl‐CoA:cholesterol acyltransferase inhibitor, in rabbit aorta and liver tissues

Abstract: A strategy for the sensitive and reliable quantitative determination of non-polar neutral compounds in biological matrices by liquid chromatography/electrospray ionization tandem mass spectrometry is described in the context of assay development for TS-962, a novel acyl-CoA:cholesterol acyltransferase (ACAT) inhibitor, in rabbit aorta and liver tissues. The electrospray ionization (ESI) mass spectrum of this compound with a mobile phase of water/acetonitrile did not give abundant [M + H]+ ions, but did give al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2001
2001
2010
2010

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…In the case of RAM sorbents, TAT depends not only on the separation time but also on the extraction time. Indeed, conventional flow rates are used for sample extraction on RAM supports and total analysis time are usually longer to 5 min [42,43,67,78,88,95,108,123,140]. Nevertheless, alkyl-diol-silica material have, recently, been found suitable for a fast and efficient sample extraction at a high flow rate [16,167].…”
Section: Analysis Timementioning
confidence: 99%
See 1 more Smart Citation
“…In the case of RAM sorbents, TAT depends not only on the separation time but also on the extraction time. Indeed, conventional flow rates are used for sample extraction on RAM supports and total analysis time are usually longer to 5 min [42,43,67,78,88,95,108,123,140]. Nevertheless, alkyl-diol-silica material have, recently, been found suitable for a fast and efficient sample extraction at a high flow rate [16,167].…”
Section: Analysis Timementioning
confidence: 99%
“…Several ml of biological fluids can be directly injected on this extraction material without loss of performances [115,116]. Capcell Pak MF [115][116][117][118][119][120][121][122][123][124][125][126][127][128][129][130][131][132][133] and Capcell Pak SCX [134] materials were suitable tools for the direct determination of drug-containing biofluids.…”
Section: Mixed-functional Materialmentioning
confidence: 99%
“…In addition to posing challenges to quantification, the matrix effect also results in the suppression of the analyte signal and lower sensitivity. Several approaches have been investigated to address matrix effects and improve sensitivity [6][7][8][9][10][11][12][13][14]. Some researchers have used post-column additions of methanoic acid [6] and trifluoroacetic acid in 2-propanol [7] into the LC flow to reduce or prevent analyte ionization suppression.…”
Section: Introductionmentioning
confidence: 99%
“…Several approaches have been investigated to address matrix effects and improve sensitivity [6][7][8][9][10][11][12][13][14]. Some researchers have used post-column additions of methanoic acid [6] and trifluoroacetic acid in 2-propanol [7] into the LC flow to reduce or prevent analyte ionization suppression. Others investigated different off-line clean-up procedures [8] and on-line LC-LC [9][10][11] to clean up the samples and to address matrix effect and reduce signal suppression.…”
Section: Introductionmentioning
confidence: 99%