ITHERM 2000. The Seventh Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.00CH3
DOI: 10.1109/itherm.2000.866843
|View full text |Cite
|
Sign up to set email alerts
|

A study of compact thermal model topologies in CFD for a flip chip plastic ball grid array package

Abstract: Phone: (5 12) 420-9273Austin, TX Tempe, A 2 ABSTRACT A previously validated detailed model of a 119-pin Flip-Chip Plastic Ball Grid Array (FC-PBGA) package was created and validated against experimental data for natural convection and forced coirvection environments. Next, two compact models were derived, a two-resistor model (created using the JEDECstandard based computational approach), and a multi-resistor model (created using the DELPHI optimization approach that was boundary condition independent within e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…The modern design for the electronic cooling of a printed circuit board (PCB) utilizes numerical techniques in order to study varying situations (Bar-Cohen et al 2001;Nakayama et al 2001;Shidore et al 2001;Watson et al 2001). Most numerical simulations are performed using commercial codes; however, as the geometries involved in this type of application become increasingly more complicated, then commercial codes have deficiencies in both accuracy and speed.…”
Section: Forced Convection Heat Transfer From Heat Sourcesmentioning
confidence: 99%
“…The modern design for the electronic cooling of a printed circuit board (PCB) utilizes numerical techniques in order to study varying situations (Bar-Cohen et al 2001;Nakayama et al 2001;Shidore et al 2001;Watson et al 2001). Most numerical simulations are performed using commercial codes; however, as the geometries involved in this type of application become increasingly more complicated, then commercial codes have deficiencies in both accuracy and speed.…”
Section: Forced Convection Heat Transfer From Heat Sourcesmentioning
confidence: 99%
“…Heat convection includes natural-convection and forced-convection [5,6]. The natural-convection heat transfer occurs mainly on the surface of the switchgears and transformers without exposure to ventilating fans.…”
Section: Heat Dissipation Of Apparatus In the Dssmentioning
confidence: 99%
“…Heat convection includes natural-convection and forced-convection [7,8]. The natural-convection heat transfer occurs mainly on the surface of the switchgears and transformers without exposure to ventilating fans.…”
Section: Heat Dissipation Of Apparatuses In Dssmentioning
confidence: 99%