A study on cycle performance variation of a linear compressor considering valve behavior

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…This is mainly due to the inertia of the valve. The inertia force is proportional to the square of the frequency [15]. Meanwhile, the slight delay of the valve closing was present when the piston was at the Top Dead Center, which also induced the backflow of the gas.…”
Section: The Discharge Valve Movements With the P-t Diagram Inside Th...mentioning
confidence: 99%
See 2 more Smart Citations
“…This is mainly due to the inertia of the valve. The inertia force is proportional to the square of the frequency [15]. Meanwhile, the slight delay of the valve closing was present when the piston was at the Top Dead Center, which also induced the backflow of the gas.…”
Section: The Discharge Valve Movements With the P-t Diagram Inside Th...mentioning
confidence: 99%
“…Some researchers have investigated the valve dynamics of the linear compressor. Park et al [15] comparatively analyzed the difference between the rigid body model and the Fluid-Structure Interaction (FSI) model of the suction valve to predict the Energy Efficiency Ratio (EER) of the compressor. The results indicated that the simple rigid body model can be used to estimate the EER of the compressor due to the low difference.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Check valve is one of the core components of scroll refrigeration compressor, which plays a decisive role on its efficiency, noise characteristic and reliability. [7][8][9] Under the refrigeration condition, the pressure ratio of scroll compressor is much larger than the volume ratio under low-temperature working condition. So a check valve device must be provided to reduce the impact of under compression on the performance of the compressor.…”
Section: Introductionmentioning
confidence: 99%
“…Hwang et al [21,22] established an FSI model to study the performance of the discharge valve. Moreover, the results showed that the valve lift obtained from the 3D fluid-structure interaction model was basically consistent with the experimental results.…”
Section: Introductionmentioning