2022
DOI: 10.3390/en15218091
|View full text |Cite
|
Sign up to set email alerts
|

A Survey of Diagnostic and Condition Monitoring of Metal Oxide Surge Arrester in the Power Distribution Network

Abstract: Metal oxide surge arresters (MOSAs) are a popular solution for dealing with overvoltages due to lightning and switching in power distribution networks. As a result, a MOSA’s performance and longevity have a significant impact on the quality of energy and the frequency of outages. A MOSA performance is determined by several elements such as leakage current, partial discharge, and thermal image measured in various ways. In this study, different techniques for diagnostic and condition monitoring of MOSAs are disc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
2

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 57 publications
0
9
0
2
Order By: Relevance
“…Deterioration or damage to MOVs results in an increase in the resistive leakage current and a decrease in the dielectric strength of MOVs, which affects the performance of surge arresters equipped with noncompliant MOVs. Therefore, it is imperative to develop reliable MOVs for use in electric power systems and in industrial and consumer electronics and to ensure the adequate monitoring of the condition of MOVs and surge arresters for the safe operation of equipment protected against temporary overvoltages and current surges [ 193 ].…”
Section: Properties Of Disc-shaped Movs From Zno-v 2 ...mentioning
confidence: 99%
“…Deterioration or damage to MOVs results in an increase in the resistive leakage current and a decrease in the dielectric strength of MOVs, which affects the performance of surge arresters equipped with noncompliant MOVs. Therefore, it is imperative to develop reliable MOVs for use in electric power systems and in industrial and consumer electronics and to ensure the adequate monitoring of the condition of MOVs and surge arresters for the safe operation of equipment protected against temporary overvoltages and current surges [ 193 ].…”
Section: Properties Of Disc-shaped Movs From Zno-v 2 ...mentioning
confidence: 99%
“…Oleh sebab itu, prediksi dan lokasi kesalahan yang akurat dan cepat di jaringan distribusi sangat penting untuk meningkatkan keandalan, penyaluran energi listrik yang optimal, dan kepuasan pelanggan dengan pelayanan energi listrik oleh PT. PLN (Persero) terutama di daerah yang jauh dari pembangkit atau pusat pelayanan penyaluran energi listrik [1]- [2]. Salah satu gangguan sistem yang umum dan berdampak negatif pada peralatan distribusi energi listrik adalah tegangan lebih.…”
Section: Pendahuluanunclassified
“…As an alternative to the above online methods, one can highlight the methods which use the monitoring of partial discharges. According to [ 17 ], partial discharges can be measured based on electrical variables (such as current pulses measured with a high frequency current transformer [ 18 ]) or as non-electrical variables (such as sound [ 19 ], light [ 20 ] and electromagnetic waves [ 21 ]).…”
Section: Introductionmentioning
confidence: 99%
“…The most-used offline methods are the reference voltage method, the power loss method and the insulation resistance method, which are briefly described bellow. These methods are commonly used in laboratories, due to limitations under operational conditions or other risks [ 17 ].…”
Section: Introductionmentioning