2010
DOI: 10.1109/tie.2009.2028815
|View full text |Cite
|
Sign up to set email alerts
|

A Synchronous Reference Frame Robust Predictive Current Control for Three-Phase Grid-Connected Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0
3

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 131 publications
(47 citation statements)
references
References 23 publications
0
44
0
3
Order By: Relevance
“…Various single loop and multiloop control systems are discussed in the literature for power droop control, voltage and current control. In which inner loop is for current regulation and outer loop is for voltage regulation [13,70,71]. In Figure 19, the categorization of classical an advanced control technique is depicted clearly.…”
Section: Control Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…Various single loop and multiloop control systems are discussed in the literature for power droop control, voltage and current control. In which inner loop is for current regulation and outer loop is for voltage regulation [13,70,71]. In Figure 19, the categorization of classical an advanced control technique is depicted clearly.…”
Section: Control Techniquesmentioning
confidence: 99%
“…Electronics 2018, 7, x FOR PEER REVIEW 18 of 37 for voltage regulation [13,70,71]. In Figure 19, the categorization of classical an advanced control technique is depicted clearly.…”
Section: Control Techniquesmentioning
confidence: 99%
“…However, a major challenge of the direct-current-based vector control mechanism is that no well-established systematical approach to tuning the PI controller gains exists, so that optimal DCC is hard to obtain. Other control methods have also been developed recently, direct power control [24][25][26] and predictive current control [27][28][29] in particular. Notwithstanding their merits, all these control methods show some limitations.…”
Section: Fig 1 Application Of Grid-connected Rectifier/inverter In mentioning
confidence: 99%
“…A multiple feedback loop controller is typically composed of voltage control in the outer loop and current control in the inner loop. Numerous control strategies such as PI [9,10], predictive control [11,12], deadbeat control [13,14], and repetitive control [15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33] are used for controlling the outer and inner loops. However, these controllers have a problem to make a design of controller optimally, which should be considered on both outer loop and inner loop.…”
Section: Introductionmentioning
confidence: 99%