1964
DOI: 10.1038/2021358a0
|View full text |Cite
|
Sign up to set email alerts
|

A Technique for Electronically Recording Aphid Feeding and Salivation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
216
0
3

Year Published

2000
2000
2016
2016

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 379 publications
(225 citation statements)
references
References 5 publications
0
216
0
3
Order By: Relevance
“…Plant penetration behavior of the aphid was monitored by application of the dc EPG technique, and waveforms were displayed and recorded by using Giga hardware and PROBE software (both from Wageningen Agricultural University, Wageningen, The Netherlands) (30,32,39,40). A gold wire electrode (2 cm long and 20 m in diameter) was attached to the dorsum of each aphid by using electrically conductive silver glue (Electrolube, Swadlincote, U.K.), and the electrode was connected to the input of an EPG amplifier.…”
Section: Epg Recording and Long-distance Signaling In Plantsmentioning
confidence: 99%
“…Plant penetration behavior of the aphid was monitored by application of the dc EPG technique, and waveforms were displayed and recorded by using Giga hardware and PROBE software (both from Wageningen Agricultural University, Wageningen, The Netherlands) (30,32,39,40). A gold wire electrode (2 cm long and 20 m in diameter) was attached to the dorsum of each aphid by using electrically conductive silver glue (Electrolube, Swadlincote, U.K.), and the electrode was connected to the input of an EPG amplifier.…”
Section: Epg Recording and Long-distance Signaling In Plantsmentioning
confidence: 99%
“…Aphids for EPG recording were attached to a gold wire (f18 mm) by means of a water-based glue droplet containing silver particles, as originally described. 14,15 Signals were acquired at a sampling rate of 100 Hz, digitized with a built-in converter, and analyzed using StyletC software (EPG Systems, Netherlands) on a PC. Since the input resistance (Ri) of the DC-EPG amplifier was 1GV, the measured voltage differences were calibrated with a pulse of known voltage (in this case, 50 mV), in order to compensate for the attenuation of the membrane potential changes due to the relatively low Ri.…”
Section: Electrophysiologymentioning
confidence: 99%
“…The standard technique for studying feeding behavior in triatomines was developed in the 1970's by Smith & Friend, based on the models already used for studies of aphids (McLean & Kinsey, 1964;Tjallingii, 1985). Smith & Friend (1970) observed the action of the cibarial pump using an electrical resistance technique, carrying out modifications in order to capture clear signals.…”
Section: History Of the Use Of Electrical Recording In The Study Of Tmentioning
confidence: 99%