2018
DOI: 10.4236/jpee.2018.68001
|View full text |Cite
|
Sign up to set email alerts
|

A Three Decades of Marvellous Significant Review of Power Quality Events Regarding Detection & Classification

Abstract: Around the globe, the necessity of green supply with a dedicated standard quality thrust of consumers is increasing day by day. The advancement in technology urges the electrical power system to deliver a high-quality rated undistorted sinusoidal current, the voltage at a constant desired standard frequency to its consumers. The present paper reveals a complete and inclusive study of power quality events, such as automatic classification and signal processing via creative techniques and the noises effect on th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 218 publications
0
7
0
Order By: Relevance
“…The performance analysis of the HPF with different inverter topology was given in Nandakumar and More [15]. Through this [15] [17]. This [17] has reviewed more than 100 publications for classifying and detecting them.…”
Section: B Filtersmentioning
confidence: 99%
See 1 more Smart Citation
“…The performance analysis of the HPF with different inverter topology was given in Nandakumar and More [15]. Through this [15] [17]. This [17] has reviewed more than 100 publications for classifying and detecting them.…”
Section: B Filtersmentioning
confidence: 99%
“…Through this [15] [17]. This [17] has reviewed more than 100 publications for classifying and detecting them. Another work of Balasubramanian et al [18] discussed the simulation and analysis of the performance of HPF with fuzzy logic implementation under the non-linear condition for PQ enhancement.…”
Section: B Filtersmentioning
confidence: 99%
“…Mitigation of power quality distortions is an active topic of research [4]. Studies in this field agree that to properly mitigate power quality distortions it is essential to detect the occurrence of the distortions and to identify their specific types [5]. Many automatic classifiers of power quality distortions have already been developed [1].…”
Section: Introductionmentioning
confidence: 99%
“…The unbalancing power consumption nature is determined by the electrical receiver's type. And if in industrial premises, where motor and other three-phase symmetrical loads prevail over single-phase electric receivers, the currents and voltages negative sequence components have the greatest values [7][8][9][10][11][12][13], then in rooms containing 1045 (2022) 012145 IOP Publishing doi:10.1088/1755-1315/1045/1/012145 2 mainly communal single-phase electric receivers, it is the zero sequence currents and voltages symmetrical components that take the greatest importance [14][15][16][17][18][19]. The criterion for evaluating additional active power losses is the power loss coefficient, which represents the active losses ratio in an unbalance mode to the corresponding losses caused by the positive sequence currents flow only [20]:…”
Section: Introductionmentioning