The article discusses distribution electrical networks 0.38 kV operating modes, feeding individual residential buildings. The electrical energy parameters measurement were certified RESURS-UF2M device carried out. The currents and voltages time diagrams based on the measurements made and using Matlab technologies were constructed. It is established that the level of phase currents unbalance is quite high and causes significant three-phase power supply system unbalance voltage accordingly. The power of quality indicators - calculations, characterizing voltage unbalance were made, which were based on the measurements and the computer program “Asymmetry” was used. As well as the additional power losses coefficient determining by the phase currents unbalance, were calculations. Time diagrams these indicators are constructed and their analysis were made. As a result, the power of quality is significantly reduced by unbalance power consumption in the studied electrical network were founded. At the same time, the additional power losses are significant increases. Specific recommendations for the normalization electrical network-operating mode are given.
This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 4.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
The purpose of this study is to study the effect of loading power transformers (PT) in their continuous use on their energy efficiency on a real-life example of existing rural electric networks. It is noted that the vast majority of PT in rural areas have a very low load factor, which leads to an increase in specific losses of electric energy when this is transmitted to various consumers. It is planned to optimize the existing synchronized power supply systems in rural areas by creating new power supply projects in such a way as to integrate existing power sources and ensure the most efficient loading of power transformers for the subsequent transfer of these systems to isolated ones that receive power from distributed generation facilities. As an example, we use data from an electric grid company on loading power transformers in one of the districts of the Irkutsk region. Issues related to the determination of electric energy losses in rural PT at different numerical values of their load factors are considered. A computing device was developed using modern programming tools in the MATLAB system, which has been used to calculate and plot the dependence of power losses in transformers of various capacities on the actual and recommended load factors, as well as the dependence of specific losses during the transit of 1 kVA of power through a power transformer at the actual, recommended and optimal load factors. The analysis of specific losses of electric energy at the actual, recommended and optimal load factors of PT is made. Based on the analysis, the intervals of optimal load factors for different rated power of PT of rural distribution electric networks are proposed. It is noted that to increase the energy efficiency of PT, it is necessary to reduce idling losses by increasing the load of these transformers, which can be achieved by reducing the number of transformers while changing the configuration of 0.38 kV distribution networks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.