A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
203
1
4

Year Published

2005
2005
2021
2021

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 258 publications
(210 citation statements)
references
References 11 publications
2
203
1
4
Order By: Relevance
“…This method resulted in a much higher recorded impedance than that of the gold traces themselves, due to the gold/HBSS and HBSS/wire interfacial resistance; regardless, this was an effective method for evaluating conductivity without damaging electrode exposures through rough contact with spectrum analyzer leads. Results for impedance testing of the electrode contacts and insulated wire traces are given in Figure 5, and show that the electrode impedances are uniform across electrodes and compare favorably to properties of rigid-MEA electrodes (Heuschkel et al, 2002;Oka et al, 1999). Impedance measurement results also indicate that the PDMS insulating layer acts well as an insulator ( Figure 5A).…”
Section: Electro-mechanical Testingmentioning
confidence: 86%
“…This method resulted in a much higher recorded impedance than that of the gold traces themselves, due to the gold/HBSS and HBSS/wire interfacial resistance; regardless, this was an effective method for evaluating conductivity without damaging electrode exposures through rough contact with spectrum analyzer leads. Results for impedance testing of the electrode contacts and insulated wire traces are given in Figure 5, and show that the electrode impedances are uniform across electrodes and compare favorably to properties of rigid-MEA electrodes (Heuschkel et al, 2002;Oka et al, 1999). Impedance measurement results also indicate that the PDMS insulating layer acts well as an insulator ( Figure 5A).…”
Section: Electro-mechanical Testingmentioning
confidence: 86%
“…However, the latter becomes more useful in studies on synaptic plasticity due to the following advan- [24] . Heuschkel et al [25] later applied this 3D MEA to acute hippocampal slices and obtained better …”
Section: Stable Field Excitatory Postsynaptic Potentials (Fepsps)mentioning
confidence: 99%
“…However, the extracellular stimulation from the array suffers from poor spatial localization (Heuschkel et al, 2002) and stimulation artifacts (Wagenaar and Potter, 2004). These stimulation issues have been circumvented by using optical stimulation of caged glutamate to stimulate neurons, while recording exracellular signals via the MEA (Ghezzi et al, 2008).…”
Section: Discussionmentioning
confidence: 99%