1970
DOI: 10.1007/bf02477245
|View full text |Cite
|
Sign up to set email alerts
|

A versatile cell detector for cell volume measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1971
1971
2003
2003

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Cell counts and cell volume determinations of the malignant T-lymphoblast cell lines MOLT-3 and Jurkat treated or untreated with TPA were determined by an electronic cell counter fitted with a pulse height analyzer as described previously by Taylor (1970). In short, MOLT-3 or Jurkat cells were cultured in a-medium supplemented with 10% fetal calf serum with or without 16 nM TPA.…”
Section: Cell Volume Determinationmentioning
confidence: 99%
“…Cell counts and cell volume determinations of the malignant T-lymphoblast cell lines MOLT-3 and Jurkat treated or untreated with TPA were determined by an electronic cell counter fitted with a pulse height analyzer as described previously by Taylor (1970). In short, MOLT-3 or Jurkat cells were cultured in a-medium supplemented with 10% fetal calf serum with or without 16 nM TPA.…”
Section: Cell Volume Determinationmentioning
confidence: 99%
“…By the late 1960s, studies related to origins of volumetric artifacts were burgeoning, 28,30,44,45,49,65–78 and several groups were building experimental systems based on the Coulter Principle. 2830,41,45–47,73,79 The troublesome sizing artifact arose when particles passed through the sensing aperture at different radial distances from its axis. 65 At low effective particle concentrations, apertures having lengths several times their diameter were shown to improve sizing resolution, 34,41,67,80 as did an auxiliary flow surrounding a smaller suspension stream so as to hydrodynamically focus particles through the aperture near its axis.…”
Section: Act IIImentioning
confidence: 99%
“…65 At low effective particle concentrations, apertures having lengths several times their diameter were shown to improve sizing resolution, 34,41,67,80 as did an auxiliary flow surrounding a smaller suspension stream so as to hydrodynamically focus particles through the aperture near its axis. [81][82][83][84][85] At typical particle concentrations, sampling signal pulses at aperture midpoint 67 or selecting them according to duration 79 substantially improved volumetric accuracy (see overviews 65,67,78,[86][87][88].…”
Section: Act IIImentioning
confidence: 99%
“…Discrimination between the red and white cells, which measure approximately 8 and 20ju,m, respectively, is obtained from the different sizes of electrical signals. 10 3.4 3.4.1…”
Section: Techniquesmentioning
confidence: 99%