2013
DOI: 10.1136/heartasia-2013-010402
|View full text |Cite
|
Sign up to set email alerts
|

Abdominal skeletal muscle twitching due to current leak from a pacemaker extension connector box

Abstract: A 51-year-old gentleman with tetralogy of Fallot underwent pulmonary valve replacement and tricuspid valve annuloplasty necessitating endocardial pacing system extraction so that the annuloplasty ring could be sited. During the same operation, an epicardial pacing system was implanted with the generator positioned subcutaneously in an epigastric position.Six months later, the box was moved to the left iliac fossa because of pocket pain and a Medtronic extension connector box was used to extend the lead so that… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Stimulation of extra-cardiac structures following pacemaker implantation is a rare occurrence that has been reported previously and is generally regarded as an uncommon complication. The published literature on this matter lists several possible complications, including the development of twiddler syndrome, the occurrence of a current leak, and phrenic nerve excitation causing diaphragmatic twitching [3][4][5].…”
Section: Discussionmentioning
confidence: 99%
“…Stimulation of extra-cardiac structures following pacemaker implantation is a rare occurrence that has been reported previously and is generally regarded as an uncommon complication. The published literature on this matter lists several possible complications, including the development of twiddler syndrome, the occurrence of a current leak, and phrenic nerve excitation causing diaphragmatic twitching [3][4][5].…”
Section: Discussionmentioning
confidence: 99%
“…Muscle twitching is one of the complications caused by a permanent cardiac pacemaker, and Twiddler syndrome, where twisting or rotating of the generator in its pocket results in lead rotation or coiling, is a common cause of this [4]. Other causes of pacemaker-induced twitching include spontaneous migration of pacemaker leads or generator, cardiac perforation, electric current leakage, and inappropriate output [5][6][7]. Therefore, the position, morphology, and settings must be checked when unexpected muscle twitching occurs in a patient with an implanted pacemaker.…”
Section: Discussionmentioning
confidence: 99%