A 51-year-old gentleman with tetralogy of Fallot underwent pulmonary valve replacement and tricuspid valve annuloplasty necessitating endocardial pacing system extraction so that the annuloplasty ring could be sited. During the same operation, an epicardial pacing system was implanted with the generator positioned subcutaneously in an epigastric position.Six months later, the box was moved to the left iliac fossa because of pocket pain and a Medtronic extension connector box was used to extend the lead so that it could be implanted in a subrectus position. Several months later, the patient presented with intermittent skeletal muscle twitching in the abdomen.Lead impedance had fallen from 746 to 562 Ohms suggestive of a current leak. A radio-opaque marker was placed over the site of maximal twitching on abdominal x-ray (figure 1) which appeared to overly a lead fracture and so the patient was admitted electively for surgical exploration. During the operation, no fracture could be identified but rather the large screws used to secure the existing lead to the connector box were exposed resulting in a current leak. Figure 2 shows the surgeon placing medical adhesive over one of the screws. Due to the infrequent use of this equipment, the insulating glue was overlooked at the time of initial implantation. This case illustrates the need for a full understanding of all pacing hardware not in routine use prior to the start of a case and the importance of close collaboration between surgeons and pacing specialists when the need arises. Competing interests None.Provenance and peer review Not commissioned; externally peer reviewed. Figure 1 A radio-opaque marker was placed over the site of maximal abdominal twitching and appeared to overly a lead fracture. Figure 2 Surgeons place medical insulating glue over the bare screws which caused the current leak.
A case is presented in which a 66-year-old man received thrombolysis for an acute ST elevation myocardial infarction (STEMI) within 6 minutes of developing chest pain. An ECG performed 10 minutes after thrombolysis showed complete resolution of the ST segment elevation and showed no other abnormality. An echocardiogram showed normal left ventricular function and there was no detectable myocardial necrosis, as evidenced by two negative troponin assays. The case clearly reinforces the benefits of the rapid delivery of thrombolysis when appropriate for patients with STEMI. Clinicians need to be aware of the benefits of early thrombolysis as laid out in the national service framework. Evidence for the early administration of thrombolysis, data from the Myocardial Infarction National Audit Project and the future with regard to improving thrombolysis times are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.