Accuracy of corneal power measurements for intraocular lens power calculation after myopic laser In situ Keratomileusis

Abstract: Purpose:To evaluate the accuracy of corneal power measurements for intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK).Methods:The study evaluated 45 eyes with a history of myopic LASIK. Corneal power was measured using manual keratometry, automated keratometry, optical biometry, and Scheimflug tomography. Different hypothetical IOL power calculation formulas were performed for each case.Results:The steepest mean K value was measured with manual keratometry (37.48 ± 2.86 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 24 publications
0
13
0
1
Order By: Relevance
“…Among these, three studies did not have percentage data, 16 studies included only one of the selected formulae, five studies were hyperopic laser refractive surgery or radial keratotomy surgery. After the exclusion of these studies, 16 articles were used for analysis [5,[12][13][14][15][16][17][22][23][24][25][26][27][28][29][30].…”
Section: Resultsmentioning
confidence: 99%
“…Among these, three studies did not have percentage data, 16 studies included only one of the selected formulae, five studies were hyperopic laser refractive surgery or radial keratotomy surgery. After the exclusion of these studies, 16 articles were used for analysis [5,[12][13][14][15][16][17][22][23][24][25][26][27][28][29][30].…”
Section: Resultsmentioning
confidence: 99%
“…Their best combination gave RPE within ±0.50 D and ±1.00 D for 67% and 93%, respectively. 44 Two recent studies compared no-history formulas with conventional formulas using TCP from an IOLMaster 700: Yeo et al found the best prediction errors using TCP with the EVO (a new unpublished formula), Barret TK NH, and Haigis formulas with 69%, 64% and 64%, respectively, within ±0.5 D and 83% within ±0.75 D for all three formulas, which was better than both the Barret TK NH and the Haigis-L. 45 Lawless et al found the best results with the Barret TK (TCP), followed by Barret TK NH and Haigis TCP with; 35%, 38% and 40%, respectively, within ±0.25 D; 75%, 63% and 60%, respectively, within ±0.50 D; 90%, 83% and 80%, respectively, within ±0.75 D. 46 Both these studies show that the use of TCP is likely to improve IOL-calculations in post-LVC patients. This could be expected as and both the Haigis-L and Barret TK NH uses a regression equation, with its inherent variance, to account for the altered corneal power in post LVC corneas.…”
Section: Discussionmentioning
confidence: 99%
“…Based on axial length, IOL power was calculated using the SRK/T, Hoffer, or Holladay formula. [ 8 ] Technicians from the ultrasonography department performed all measurements using a consistent standard to minimize inter-observer variation.…”
Section: Methodsmentioning
confidence: 99%