2007
DOI: 10.1016/s1081-1206(10)60618-7
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of IgE antibody laboratory results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
77
1
3

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 114 publications
(82 citation statements)
references
References 24 publications
1
77
1
3
Order By: Relevance
“…Until now, the predictive values of sIgE in food allergy have been determined mostly using the ImmunoCAP system, making interpretation of the values measured by other assays difficult. Some reports argue that 3gAllergy overestimates IgE values 4, 6 However, assays from different vendors commonly produce disparate values, and in any assay comparison, it is expected that there will be differences between the reference assay and the comparison assay. In one study, for example, 3gAllergy appeared to underperform ImmunoCAP 4.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Until now, the predictive values of sIgE in food allergy have been determined mostly using the ImmunoCAP system, making interpretation of the values measured by other assays difficult. Some reports argue that 3gAllergy overestimates IgE values 4, 6 However, assays from different vendors commonly produce disparate values, and in any assay comparison, it is expected that there will be differences between the reference assay and the comparison assay. In one study, for example, 3gAllergy appeared to underperform ImmunoCAP 4.…”
Section: Discussionmentioning
confidence: 99%
“…Some reports argue that 3gAllergy overestimates IgE values 4, 6 However, assays from different vendors commonly produce disparate values, and in any assay comparison, it is expected that there will be differences between the reference assay and the comparison assay. In one study, for example, 3gAllergy appeared to underperform ImmunoCAP 4. However, at least one study has shown that in terms of assay performance – including accuracy and reproducibility – the 3gAllergy system appears to be comparable to the ImmunoCAP system 1.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorometric assays have permitted the development of automatized systems, resulting in improved reproducibility, diminished operator involvement, with reduction of mistakes, and increased sensitivity and specificity when compared with other innovative methods based on chemiluminescence [27,28]. FEIA technology opens the possibility to screen sIgE to several allergens at the same time and with few volume of sample [29].…”
Section: Fluorescent Enzyme Immune Assay (Feia)mentioning
confidence: 99%
“…Согласно лаборатор-ным стандартам ВОЗ 1 МЕ/мл (МЕ -международ-ная единица) соответствует 2,4 нг/мл иммуноглобу-лина Е. Концентрацию IgE определяют либо в МЕ/ мл, либо в кЕ/л (кЕ/л -килоединица). Сравнитель-ные исследования воспроизводимости, чувстви-тельности и специфичности определения уровня общего IgE на автоматизированных тест-системах ImmunoCap (ThermoFisher, «Phadia»), Immulite («Siemens»), двух ведущих компаний, специализи-рующихся на диагностике аллергии, продемонстри-ровали полное совпадение результатов тестов и со-ответствие стандарту 75/502 [15][16][17][18].…”
unclassified