2014
DOI: 10.5624/isd.2014.44.4.257
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

Abstract: PurposeThis study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT).Materials and MethodsForty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
15
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 15 publications
2
15
0
Order By: Relevance
“…CBCT posterior‐anterior cephalograms are shown to be more accurate than conventionally obtained extraoral cephalograms, in which transverse measurements may be impacted by changes in head position and head movements 60 . In dental implant treatment planning, one of the most frequently reported applications of CBCT is the ability to obtain height and width linear measurements of the alveolar ridge 61‐75 …”
Section: Resultsmentioning
confidence: 99%
“…CBCT posterior‐anterior cephalograms are shown to be more accurate than conventionally obtained extraoral cephalograms, in which transverse measurements may be impacted by changes in head position and head movements 60 . In dental implant treatment planning, one of the most frequently reported applications of CBCT is the ability to obtain height and width linear measurements of the alveolar ridge 61‐75 …”
Section: Resultsmentioning
confidence: 99%
“…High interobserver and intraobserver CBCT reliability was reported by Moshfeghi et al11 and Kamburoğlu et al7, while in the study by Nikneshan et al1, reproducibility for all orientations was greater than 0.9.…”
Section: Discussionmentioning
confidence: 78%
“…The accuracy and reliability of linear measurements in cone-beam computed tomography (CBCT) images has been established in several published scientific studies,1234567891011 including studies where they have been obtained from CBCT-derived models 212…”
Section: Introductionmentioning
confidence: 99%
“…In this study, terms like “true” and “false” positive and negative findings were used for readability, but one has to be aware that, even though a CBCT is rather an accurate imaging modality, there may well be a discrepancy between the images and the actual clinical condition. For instance, mean discrepancies from linear measurements of −0.17 ± 0.53 mm were observed for the mandible or less than 0.5 mm . Safety margins were taken into account when assessing the bone volume on the CBCT images as described earlier.…”
Section: Discussionmentioning
confidence: 99%
“…For instance, mean discrepancies from linear measurements of −0.17 1 0.53 mm were observed for the mandible 21 or less than 0.5 mm. 22 Safety margins were taken into account when assessing the bone volume on the CBCT images as described earlier.…”
Section: Comparison Of Radiological Implant Planning Proceduresmentioning
confidence: 99%