2017
DOI: 10.5624/isd.2017.47.1.11
|View full text |Cite
|
Sign up to set email alerts
|

Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

Abstract: PurposeThis study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes.Materials and MethodsA cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
1

Year Published

2018
2018
2019
2019

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 27 publications
0
2
0
1
Order By: Relevance
“…However, the use of a smaller voxel size results in a higher dose of radiation (4). Considering the voxel size is related to the ionizing radiation dose supplied to the patient, it certainly deserves special consideration.…”
Section: Introductionmentioning
confidence: 99%
“…However, the use of a smaller voxel size results in a higher dose of radiation (4). Considering the voxel size is related to the ionizing radiation dose supplied to the patient, it certainly deserves special consideration.…”
Section: Introductionmentioning
confidence: 99%
“…Da Silva et al. [18] measured the error between linear distance in an axial CBCT image and the actual value using a phantom (diameter, 5 cm; length, 10 cm; and a 1-mm ditch), and observed the superior accuracy of distance measurements in the axial direction. Patcas et al.…”
Section: Discussionmentioning
confidence: 99%
“…KIBT görüntülerinin çözünürlüğünün yüksek olması detayın ölçülebildiği doğruluğu belirlediğinden, analizlerin etkinliğini artırır. KIBT görüntülerinde doğrusal ölçümlerin doğruluğu üzerine yapılan birçok araştırmada, doğrusal ölçüm yönteminin güvenilir ve uygulanabilir bir yöntem olduğu belirtilmiştir (11)(12)(13). Literatür incelemeleri neticesinde çalışmamızda kullandığımız One Curve (Micro-Mega, Besançon, Fransa), Hyflex EDM (Coltene-Whaledent,Altstatten, İsviçre) ve WaveOne GOLD (Dentsply Sirona Endodontics, Ballaigues, İsviçre) eğelerinin şekillendirme etkinliklerinin KIBT kullanılarak değerlendirildiği bir çalışmaya rastlanmamıştır.…”
Section: Introductionunclassified