2009
DOI: 10.1007/978-3-642-03906-5_90
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Optical Localizers for Computer Aided Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…NDI HPS is an optical measurement system that collects the space coordinates of passive markers affixed to the application-specific tool, and the accuracy of tracked passive markers is 0.25 mm root mean square [30]. With the help of HPS, the position and orientation of tools can be determined.…”
Section: Apparatusmentioning
confidence: 99%
“…NDI HPS is an optical measurement system that collects the space coordinates of passive markers affixed to the application-specific tool, and the accuracy of tracked passive markers is 0.25 mm root mean square [30]. With the help of HPS, the position and orientation of tools can be determined.…”
Section: Apparatusmentioning
confidence: 99%
“…The handedness of the found constellation is investigated by calculating the determinant of the viewing directions of the first, fifth, and third entry of the current square candidate. If this determinant is negative, the square IDs are stored clockwise and have to be resorted as follows: 7 The last step of the algorithm determines the type of the square tracker by investigating which outer markers are tagged by the tagging markers of the two side triplets (see Fig. 4 right):…”
Section: Combining Tripletsmentioning
confidence: 99%
“…A thorough comparison of Stryker's FP 6000 (used in "Peerto-peer tracking versus Stryker FP 6000" section) against a coordinate measurement machine can be found in [7]. Elfring et al conclude that the Stryker camera exhibits best-in-class accuracy with a trueness of 0.07 mm.…”
Section: Peer-to-peer Tracking Versus Ground Truthmentioning
confidence: 99%
“…Particularly mobile measuring systems based on infrared stereophotogrammetry could be established in several industrial and clinical application areas. [2], [14] In principle the described available measuring systems are sufficient to determine the current position of the patient couch in the working space with adequate accuracy. Furthermore supplementary equipment is available for most systems enabling automatic measuring of the orientation.…”
Section: A Sensor Systems For Pose Measuring Of Robotsmentioning
confidence: 99%