2021
DOI: 10.1016/j.jormas.2020.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of orthognathic surgery with customized titanium plates – Systematic review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
17
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 33 publications
2
17
0
Order By: Relevance
“…Lastly, customized titanium plate shape and thickness can be designed preoperatively to endure soft tissue tension and mastication. 8,9,[15][16][17] x-, y-, z-axis measurements at 7 maxillary landmarks using superimposition software program of virtual surgery data and postoperative CBCT image confirmed an error <1 mm. Posterior landmarks exhibited relatively larger range of errors, possibly due to measurement errors which may occur during acquisition of STL file and superimposition with T1 and Tv.…”
Section: Discussionmentioning
confidence: 80%
See 2 more Smart Citations
“…Lastly, customized titanium plate shape and thickness can be designed preoperatively to endure soft tissue tension and mastication. 8,9,[15][16][17] x-, y-, z-axis measurements at 7 maxillary landmarks using superimposition software program of virtual surgery data and postoperative CBCT image confirmed an error <1 mm. Posterior landmarks exhibited relatively larger range of errors, possibly due to measurement errors which may occur during acquisition of STL file and superimposition with T1 and Tv.…”
Section: Discussionmentioning
confidence: 80%
“…Virtual surgery-based cutting guides and plates are used to shorten surgical time as well as increase accuracy of surgery. Lastly, customized titanium plate shape and thickness can be designed preoperatively to endure soft tissue tension and mastication 8,9,15–17 . x- , y- , z -axis measurements at 7 maxillary landmarks using superimposition software program of virtual surgery data and postoperative CBCT image confirmed an error <1 mm.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Patient-customized OGS using customized fixation plate after the virtual simulation is a more effective strategy than using CAD-CAM splints alone [ 25 ]; however, some errors in the diagnosis and treatment planning may occur due to limitations in manipulating 3D data on a 2D screen [ 26 ]. In this study, we used customized guides, plates and PSPDs for OGS.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, it provides a methodology to measure the 3D volume of the space between the condyle and fossa. Although the accuracy of OGS using a customized plate has been reported [ 25 , 26 ], surgeons and orthodontic doctors should be aware of the possible errors in surgery due to improper process of collecting patient-related data, processing digital data, and fabrication of patient-customized materials.…”
Section: Discussionmentioning
confidence: 99%