2011
DOI: 10.1039/c0ja00167h
|View full text |Cite
|
Sign up to set email alerts
|

Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS

Abstract: Techniques for the separation of small quantities of Cr from carbonate material and for the analysis of stable Cr isotopes in carbonates by MC-ICP-MS are presented in this study. In comparison with previously published methods, we have developed a one-step Cr separation procedure that is relatively simple, and has a low blank (0.12-0.20 ng). Moreover, careful optimisation of the desolvating sample introduction system allows a significant increase in the sensitivity of our MC-ICP-MS technique compared to previo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

6
57
2

Year Published

2014
2014
2025
2025

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 94 publications
(65 citation statements)
references
References 33 publications
6
57
2
Order By: Relevance
“…The average Cr recovery of our method (65%) is on par with that of (Chris Holmden, personal communication). We were unable to ascertain the total recovery of the other Cr seawater isotope method from the literature , but it appears to be < 80% (Bonnand et al, 2011). The total procedural Cr blank of our method (0.017 nmol) is of the same magnitude than that of and significantly lower than that of (up to 0.93 nmol).…”
Section: Discussionmentioning
confidence: 94%
“…The average Cr recovery of our method (65%) is on par with that of (Chris Holmden, personal communication). We were unable to ascertain the total recovery of the other Cr seawater isotope method from the literature , but it appears to be < 80% (Bonnand et al, 2011). The total procedural Cr blank of our method (0.017 nmol) is of the same magnitude than that of and significantly lower than that of (up to 0.93 nmol).…”
Section: Discussionmentioning
confidence: 94%
“…Of these three methods, the double-spike approach provides the most robust correction for instrumental and laboratory mass fractionation [4], and protocols are now in place for the isotopic analysis of several elements such as Ba, Ca, Cd, Hg, Ge, Mo, Ni, Pb, Pt, Se, U, and Zn [e.g., [6][7][8][9][10][11][12][13][14][15][16][17][18]. However, a more widespread adoption of double-spike protocols has been hindered by perceived difficulties in proper double-spike calibration, mathematical inversion [19], and fear of memory effects [20].…”
Section: Introductionmentioning
confidence: 99%
“…This solution was added to the extraction columns loaded with 2 mL of pre-cleaned Dowex AG50W-X8 cation resin (200-400 mesh). The extraction procedure principally adhered to that published by Bonnand et al (2011) and Trinquier et al (2008) with only small modifications. The final Cr-bearing liquid cut was dried down at 130 • C, ready to be loaded for Cr isotopic analysis on the thermal ionization mass spectrometer.…”
Section: Ion Chromatographic Separation Of Chromiummentioning
confidence: 99%