2020
DOI: 10.1063/5.0005320
|View full text |Cite
|
Sign up to set email alerts
|

Achieving μeV tunneling resolution in an in-operando scanning tunneling microscopy, atomic force microscopy, and magnetotransport system for quantum materials research

Abstract: Research in new quantum materials requires multi-mode measurements spanning length scales, correlations of atomic-scale variables with a macroscopic function, and spectroscopic energy resolution obtainable only at millikelvin temperatures, typically in a dilution refrigerator. In this article, we describe a multi-mode instrument achieving a μeV tunneling resolution with in-operando measurement capabilities of scanning tunneling microscopy, atomic force microscopy, and magnetotransport inside a dilution refrige… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 53 publications
1
18
0
Order By: Relevance
“…Measurements of macroscopic and microscopic quantum Hall properties were made using an instrument that is capable of simultaneous magnetotransport, scanning tunneling microscopy, and AFM measurements on a given device at ultralow temperatures 37 , 38 . The instrument was operated at 10 mK for all measurements with a perpendicular magnetic field up to 15 T. Magnetotransport measurements of the Hall and longitudinal resistances are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Measurements of macroscopic and microscopic quantum Hall properties were made using an instrument that is capable of simultaneous magnetotransport, scanning tunneling microscopy, and AFM measurements on a given device at ultralow temperatures 37 , 38 . The instrument was operated at 10 mK for all measurements with a perpendicular magnetic field up to 15 T. Magnetotransport measurements of the Hall and longitudinal resistances are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Using the probe tip reflection, a tip-sample gap of the order of 100 µm is set at room temperature. The module is then transferred and locked into the dilution refrigerator multimode SPM system where it is cooled to a temperature of 10 mK 37 , 38 . The landing region is scanned, and a ridge is identified after approaching the fan-shaped runway surface.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1, we utilized the Josephson peak of a superconductor-insulator-superconductor (SIS) junction as a noise sensor. [40][41][42] We prepared a Re(0001) sample by initial cycles of Ar + sputtering, followed by subsequent cycles of O 2 annealing (T ∼ 1500 K) and flash annealing (T ≙ 1830 K). Then, we picked up a Re cluster on a W tip to obtain an asymmetric SIS junction of 2(Δ 1 + Δ 2 ) ≈ 2.23 mV [Fig.…”
Section: Energy Resolution Of the Mk Esr-stm Setupmentioning
confidence: 99%
“…We numerically check the robustness of the one-sided hinge states against weak disorder, and expect the one-sided hinge states to be detectable in the state-of-the-art scanning tunneling Hall measurement (Fig. 4) [77]. This work will not only help identify the Fermi-arc 3D quantum Hall effect but also be insightful for searching for higher-order topological states of matter.…”
Section: Gap Gap Gapmentioning
confidence: 86%