2018
DOI: 10.1109/tia.2018.2855128
|View full text |Cite
|
Sign up to set email alerts
|

Active Disturbance Rejection Control of LCL-Filtered Grid-Connected Inverter Using Padé Approximation

Abstract: In this paper, a simplified robust control is proposed to improve the performance of a three-phase current controlled volt age source inverter connected to the grid through an inductivecapacitive-inductive (LCL) filter. The presence of the LCL-filter resonance complicates the dynamics of the control system and lim its its overall performance, particularly when disturbances and parametric uncertainty are considered. To solve this problem, a robust active damping method based on the linear active distur bance re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 86 publications
(32 citation statements)
references
References 29 publications
0
32
0
Order By: Relevance
“…The ADRC estimates all the exogenous and endogenous disturbances, as a value called the lumped disturbance, in the system with the model-independent extended state observer (ESO), which is the main part of ADRC, and compensates them in the control law [19]. The reduction of the resonance harmonics for the LCL filter type GCI was investigated with ADRC in [20][21][22].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The ADRC estimates all the exogenous and endogenous disturbances, as a value called the lumped disturbance, in the system with the model-independent extended state observer (ESO), which is the main part of ADRC, and compensates them in the control law [19]. The reduction of the resonance harmonics for the LCL filter type GCI was investigated with ADRC in [20][21][22].…”
Section: Literature Reviewmentioning
confidence: 99%
“…In general, the relationship between ω o and ω c is ω o = 3 ∼ 10ω c [10], in this paper, however, it is ω o = 6ω c . If the control effect needs to be further optimized, the influence of each parameter in [34] on the decoupling and stability of the system can be obtained. This paper only gives a conclusion:…”
Section: Controller Designmentioning
confidence: 99%
“…The effectiveness of ADRC has been tested in many industrial applications and theoretical case studies such as motion control [28], grid connected inverter [29], buck converter [30], permanent magnet synchronous motor [31] and ALSTOM gasifier benchmark problem [32]. Zheng and Gao [33] summarise the performance of ADRC in several practical applications such as motion control and web tension regulation.…”
Section: Introductionmentioning
confidence: 99%