2010 Ieee Andescon 2010
DOI: 10.1109/andescon.2010.5631646
|View full text |Cite
|
Sign up to set email alerts
|

Active power filters: A comparative analysis of current control techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…In order to demonstrate the operation principle of the proposed topology, key computer simulation results were obtained for the conventional SAPF, represented in Figure 1, and for the proposed SAPF with modified dc-link, represented in Figure 2, where were considered inductors, LDC, of 200 mH and 50 mH, respectively. Figure 4 shows the current in dc-link in both topologies, whose current regulation was made through a PI controller presented in [23], for a reference of 20 A. It is important to note that the gains of the PI controller influence the overshoot observed in both simulation results.…”
Section: Proposed Control Algorithmmentioning
confidence: 99%
“…In order to demonstrate the operation principle of the proposed topology, key computer simulation results were obtained for the conventional SAPF, represented in Figure 1, and for the proposed SAPF with modified dc-link, represented in Figure 2, where were considered inductors, LDC, of 200 mH and 50 mH, respectively. Figure 4 shows the current in dc-link in both topologies, whose current regulation was made through a PI controller presented in [23], for a reference of 20 A. It is important to note that the gains of the PI controller influence the overshoot observed in both simulation results.…”
Section: Proposed Control Algorithmmentioning
confidence: 99%
“…Fig. 3 shows the current in dc-link in both topologies, whose current regulation was made through a PI controller presented in [18], for a reference of 20 A. It is important to note that the gains of the PI controller influence the overshoot observed in both simulation results.…”
Section: Proposed Control Algorithmmentioning
confidence: 99%
“…Shunt Active Filter (SAF), a specific type of APF, can effectively compensate the harmonic current of nonlinear loads (Cavini et al, 2004), injecting the detected currents distortions with reverse polarity, so getting its cancellation. Thus, several control strategies have been developed for this topology (Caceres et al, 2010;Buso et al, 1998).…”
Section: Introductionmentioning
confidence: 99%